Skip to content

BIORAPTOR/ULTRABRAID 72200774Recalls & reported problems

Smith & Nephew, Inc. · BIORAPTOR 2.9 WITH 1 ULTRABRAID · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 03596010585950), received between Aug 31, 2017 and Jan 12, 2018 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

40 other recalls cover devices cleared under the same FDA submission (K151105); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Break1
  • Device Operates Differently Than Expected1

Patient problems

  • No Known Impact Or Consequence To Patient2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 12, 2018Device Operates Differently Than Expected

    IT WAS REPORTED THAT DURING A SHOULDER SUPERIOR LABRUM REPAIR ONE SUTURE WAS PASSED THROUGH THE LABRUM AND THE OTHER ONE WAS HELD AND THIS SUTURE WAS LEAVED FROM THE ANCHOR FOR AN UNKNOWN REASON. ANCHOR WAS NOT REMOVED AND AN ADDITIONAL HOLE WAS MADE TO COMPLETE THE PROCEDURE, NO SIGNIFICANT DELAY OR PATIENT INJURY REPORTED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7186930 ↗
  • MalfunctionAug 31, 2017Break

    IT WAS REPORTED THAT THE SCREW WAS BROKEN DURING INSERTION. ALL PIECES OF THE SCREW WERE REMOVED FROM THE PATIENT. A BACKUP DEVICE WAS AVAILABLE TO COMPLETE THE PROCEDURE FOLLOWING A SHORT DELAY. NO PATIENT IMPACT WAS REPORTED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6836626 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K151105. One submission often covers many models, so check the product and lot details in each record.

  • Z-0138-2021 · Sep 9, 2020 · Open, Classified
    TWINFIX 5.0MM AB SUTURE ANCHOR-Absorbable Suture anchors Product Number: 7210711
  • Z-0171-2021 · Sep 9, 2020 · Open, Classified
    HEALICOIL RG SA 5.5MM W/3 UB-BL CB BL BK- Absorbable Suture anchor Product Number: 72203707
  • Z-0173-2021 · Sep 9, 2020 · Open, Classified
    HEALICOIL RSB SA 5.5MM W/1 UT & 1 UB BL- Absorbable Suture anchor Product Number: 72203801
  • Z-0155-2021 · Sep 9, 2020 · Open, Classified
    TWINFIX ULTRA 5.5MM PLLA/HA 2 UBWHT/BL--Absorbable Suture anchor Product Number: 72202602
  • Z-0137-2021 · Sep 9, 2020 · Open, Classified
    TWINFIX 5.0MM AB SUTURE ANCHOR WITH TWO- Absorbable Suture anchors Product Number: 7210710
  • Z-0142-2021 · Sep 9, 2020 · Open, Classified
    TWINFIX AB 5.0 SUTR ANCHR W/2 38 DURAB-Absorbable Suture anchors Product Number: 72200785
  • Z-0141-2021 · Sep 9, 2020 · Open, Classified
    TWINFIX AB 5.0 SUTR ANCHR W/2 38 ULTRA-Absorbable Suture anchors Product Number:72200777
  • Z-0165-2021 · Sep 9, 2020 · Open, Classified
    OSTEORAPTOR CRVD 2.3 SA UB COBRD BLUE- Absorbable Suture anchor Product Number: 72203290
  • Z-0169-2021 · Sep 9, 2020 · Open, Classified
    HEALICOIL RSB SA 4.75MM W/1 UT & 1 UB BK-- Absorbable Suture anchor Product Number: 72203705
  • Z-0163-2021 · Sep 9, 2020 · Open, Classified
    TWINFIX ULTRA HA 5.5 W/2 UB BLUE & BLK- Absorbable Suture anchor Product Number: 72202626
  • Z-0146-2021 · Sep 9, 2020 · Open, Classified
    BIORAPTOR 2.9MM SUTURE ANCHOR-Absorbable Suture anchor Product Number: 72201702
  • Z-0152-2021 · Sep 9, 2020 · Open, Classified
    OSTEORAPTOR 2.9 W/ 2 UB WHITE / BLUE -Absorbable Suture anchor Product Number: 72201995
  • Z-0162-2021 · Sep 9, 2020 · Open, Classified
    TWINFIX ULTRA HA 4.5 W/2 UB BLUE & BLK- Absorbable Suture anchor Product Number: 72202624
  • Z-0157-2021 · Sep 9, 2020 · Open, Classified
    TWINFIX ULTRA 6.5MM PLLA/HA 2 UBWHT/BL-Absorbable Suture anchor Product Number: 72202608
  • Z-0151-2021 · Sep 9, 2020 · Open, Classified
    OSTEORAPTOR 2.9 W/ 1 UB COBRAID BLUE -Absorbable Suture anchor Product Number: 72201994

…and 25 more.