Skip to content

Peri-Loc 71867066Recalls & reported problems

Smith & Nephew, Inc. · PERI-LOC 4.5MM T25 TITANIUM LOCKING SCREW 66MM SELF-TAPPING · Class 2

All models of Peri-Loc (102)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03596010641694), received between Jun 29, 2021 and Jun 29, 2021 — classified as 1 malfunction.

The most frequently reported specific device problem is “Connection Problem” (1 report).

2 other recalls cover devices cleared under the same FDA submission (K083032, K210837); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Connection Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 29, 2021Connection Problem; Connection Problem

    IT WAS REPORTED THAT, DURING A TRAUMA SURGERY WHILE THE INSTRUMENT WAS INSIDE OF THE PATIENT, THE SCREW WAS NOT LOCKED AND PENETRATED THE HOLE ON THE PLATE. THE PERI-LOC 4.5MM TI L-D FEM PL 8H L 193MM, PERI-LOC 4.5MM T25 TI LCK SCR 66MM S-T, TWO (2) PERI-LOC 4.5MM T25 TI LCK SCR 64MM S-T AND PERI-LOC 4.5MM T25 TI LCK SCR 58MM S-T; IT WAS UNKNOWN IF THE PLATE OR WHICH SCREWS REPORTED WERE DEFECTIVE. THE PROCEDURE WAS SUCCESSFULLY COMPLETED PUTTING BACK AND ROTATING IN AN OPPOSITE DIRECTION WITHOUT DELAY USING THE SAME DEVICE. PATIENT WAS NOT HARMED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12082287 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K083032, K210837. One submission often covers many models, so check the product and lot details in each record.

  • Z-0373-2016 · Oct 20, 2015 · Terminated
    Smith & Nephew PERI-LOC VOLAR DISTAL RADIUS PLATE STANDARD 3 HOLE SHORT, RIGHT - 62 MM, STERILE R, Rx only, REF Numbers: 71863114 Bone fixation plate
  • Z-0372-2016 · Oct 20, 2015 · Terminated
    Smith & Nephew PERI-LOC VOLAR DISTAL RADIUS PLATE STANDARD 3 HOLE SHORT, LEFT - 62 MM, STERILE R, Rx only, REF Numbers: 71863110 Bone fixation plate

Other PLATE, FIXATION, BONE devices

All PLATE, FIXATION, BONE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page