STA R Max® (with cap piercing option) 59027Recalls & reported problems
Diagnostica Stago · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 03607450590272), received between Oct 28, 2022 and Aug 10, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “False Negative Result” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K082675, K093001, K151867, K212183, K983460); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- False Negative Result1
- Low Test Results1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 10, 2023Low Test Results; Low Test Results
ON (B)(6) 2023, THE INSTRUMENT PRODUCED A HEPARIN (UFH) RESULT FOR 1 PATIENT (ID: (B)(6)) :UFH = 0.00 UI/ML (<0.1 UI/ML). PHARMACY QUESTIONED THE RESULT WHICH CAUSED THE LABORATORY TO RERUN THE SAMPLE. SAMPLE WAS RERAN ON THE SAME INSTRUMENT, THE RESULT WAS 0.76 UI/ML. SAMPLE WAS CAPPED. ACCORDING TO THE CUSTOMER, THE ERRONEOUS RESULT HAS BEEN RELEASED BUT TREATMENT WAS NOT CHANGED. NO SERIOUS INJURY OR DEATH HAVE BEEN REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17497291 ↗MalfunctionOct 28, 2022False Negative Result; False Negative Result
ON (B)(6) 2021, THE INSTRUMENT PRODUCED A CRITICAL HEPARIN (UFH) RESULT FOR 1 PATIENT :UFH = 0 UI/ML. THE SAMPLE WAS REMOVED FROM THE UNIT AND WAS CHECKED FOR CLOTS, RE-SPUN, AND RERUN WITHOUT THE CAP AND FOUND AT 0.78 UI/ML. ACCORDING TO THE CUSTOMER, THE ERRONEOUS RESULT WAS NOT RELEASED AND NO SERIOUS INJURY RESULTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15691065 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K082675, K093001, K151867, K212183, K983460. One submission often covers many models, so check the product and lot details in each record.
- Z-1575-2023 · Mar 22, 2023 · Open, ClassifiedSTA R Max fully automatic clinical instrument designed to perform tests on human plasmas, Reference Numbers 59013 and 59026
- Z-0899-03 · Mar 5, 2003 · TerminatedSTA-Compact Hemostasis System with Cap piercing capability.
Other SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES devices
- ACL TOP 970 CL 00000280097Instrumentation Laboratory Company · System, Multipurpose For In Vitro Coagulation Studies2 recalls0 reports
- TEG5000 HEMOSTASIS ANALYZER 07-022Haemonetics Corporation · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall2 reports
- STA Satellite® 58104Diagnostica Stago · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall1 report
- ACL ELITE 00000880311Instrumentation Laboratory Company · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall0 reports
- ACL ELITE PRO 00001000311RInstrumentation Laboratory Company · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall0 reports
- ACL ELITE PRO 00001000311Instrumentation Laboratory Company · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall0 reports
- ACL ELITE 00000880311RInstrumentation Laboratory Company · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall0 reports
- Hemochron Whole Blood Microcoagulation System ELITEAccriva Diagnostics Holdings, Inc. · System, Multipurpose For In Vitro Coagulation Studies2 deaths13 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page