AESCULAP FF856RRecalls & reported problems
Aesculap AG · CASPAR Rongeur, straight, 7" (180 mm), heavy pattern, width: 3 mm · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04038653164523), received between Feb 10, 2021 and Feb 10, 2021 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break2
- Fracture2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 10, 2021Break; Fracture; Break; Fracture
IT WAS REPORTED THAT THERE WAS AN ISSUE WITH FF856R - CASPAR OSTEOPHYTE RONGHV-DTY3MM180MM. ACCORDING TO THE COMPLAINT DESCRIPTION, THE ITEM IS BROKEN (INCIDENT). IT OCCURRED DURING A CERVICAL PROCEDURE AND THERE WERE NO BROKEN PIECES. THERE WAS NO DESCRIBED PATIENT HARM. ADDITIONAL INFORMATION WAS NOT PROVIDED NOR AVAILABLE / WAS NOT AVAILABLE. THE MALFUNCTION IS FILED UNDER AAG REFERENCE (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11309017 ↗MalfunctionFeb 10, 2021Break; Fracture; Break; Fracture
IT WAS REPORTED THAT THERE WAS AN ISSUE WITH FF856R - CASPAR OSTEOPHYTE RONGHV-DTY3MM180MM. ACCORDING TO THE COMPLAINT DESCRIPTION, THE ITEM IS BROKEN. IT OCCURRED DURING A CERVICAL PROCEDURE AND THERE WERE NO BROKEN PIECES. THERE WAS NO DESCRIBED PATIENT HARM. ADDITIONAL INFORMATION WAS NOT PROVIDED NOR AVAILABLE / WAS NOT AVAILABLE. THE ADVERSE EVENT / MALFUNCTION IS FILED UNDER AAG REFERENCE (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11309000 ↗
FDA clearance and classification
The FDA regulates product code HTX (rongeur) under 21 CFR 888.4540 as a Class I device. 21 CFR 888.4540 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the AESCULAP FF856R
Has the AESCULAP FF856R been recalled?
No FDA recall record in our data names this exact device identifier (DI 04038653164523), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the AESCULAP FF856R?
The FDA's MAUDE database lists 2 adverse event reports for this device, received on Feb 10, 2021. In those reports, the most common specific device problems are “Break” (2) and “Fracture” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the AESCULAP FF856R?
None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the AESCULAP FF856R FDA approved?
Devices of this type (product code HTX) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Aesculap AG.
Who makes the AESCULAP FF856R, and is it still sold?
The FDA's device database lists Aesculap AG as the company responsible for it (brand AESCULAP, model FF856R). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other RONGEUR devices
- SPOTLIGHT 292904201Depuy Spine, LLC · RONGEUR6 reports
- Symmetry RapidClean® 58-3200J-BDAspen Surgical Products, Inc. · Rongeur5 reports
- SPOTLIGHT 292904202Medos International Sàrl · RONGEUR5 reports
- NA 03.605.001Synthes GmbH · RONGEUR4 reports
- Symmetry Rapidclean® 58-3200-BDAspen Surgical Products, Inc. · Rongeur3 reports
- AESCULAP FF805RAesculap AG · RONGEUR3 reports
- Medicon 57.28.33Medicon eG. Chirurgiemechaniker-Genossenschaft · RONGEUR3 reports
- SPOTLIGHT 292902240Depuy Spine, LLC · RONGEUR3 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page