OLYMPUS Winter & Ibe GmbH · Telescope "TrueView II", 4 mm, 30°, autoclavable · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Quick summary

This Olympus TrueView arthroscope is a rigid joint-viewing scope. Of its 163 adverse event reports, 162 are malfunctions and 1 is an injury, with no deaths. Many describe breaks, cracked cover glass, and damaged tips that were melted, burnt, or worn. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
164
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 164 adverse event reports that list this exact device (DI 04042761010542), received between Jun 1, 2022 and Sep 17, 2026 — classified as 1 injury, 163 malfunctions.

The most frequently reported specific device problem is “Break” (90 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 2 reportsDec 2023: 2 reportsJan 2024: 5 reportsFeb 2024: 3 reportsMar 2024: 8 reportsApr 2024: 6 reportsMay 2024: 5 reportsJun 2024: 7 reportsJul 2024: 1 reportsAug 2024: 3 reportsSep 2024: 2 reportsOct 2024: 5 reportsNov 2024: 3 reportsDec 2024: 2 reportsJan 2025: 0 reportsFeb 2025: 3 reportsMar 2025: 6 reportsApr 2025: 1 reportsMay 2025: 4 reportsJun 2025: 5 reportsJul 2025: 5 reportsAug 2025: 5 reportsSep 2025: 0 reportsOct 2025: 2 reportsNov 2025: 3 reportsDec 2025: 6 reportsJan 2026: 6 reportsFeb 2026: 5 reportsMar 2026: 5 reportsApr 2026: 4 reportsMay 2026: 2 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520268
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break90
  • Detachment of Device or Device Component17
  • Crack11
  • Scratched Material8
  • Thermal Decomposition of Device8
  • Melted5
  • Degraded4
  • Fracture4

Patient problems

  • No Clinical Signs, Symptoms or Conditions163
  • Foreign Body In Patient1

Recent adverse event reports

The 25 most recent of 164 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 17, 2026Break

    The customer reported distal end chipped during reprocessing involving an Olympus Rigid arthroscope. There was no patient involvement.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50805825 ↗
  • MalfunctionJul 27, 2026Break

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50018886 ↗
  • MalfunctionMay 23, 2026Overheating of Device

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE HAD MELTED DISTAL END. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25263398 ↗
  • MalfunctionMay 14, 2026Crack

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE EXHIBITED CRACKED COVER GLASS AT DISTAL END. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25170015 ↗
  • MalfunctionApr 23, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE COVER GLASS OF THE RIGID ARTHROSCOPE WAS DAMAGED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24967860 ↗
  • MalfunctionApr 17, 2026Break; Poor Quality Image

    NO ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24911848 ↗
  • MalfunctionApr 16, 2026Flare or Flash

    NO ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24897438 ↗
  • MalfunctionApr 1, 2026Naturally Worn

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE HAD WORN DISTAL END. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24755687 ↗
  • MalfunctionMar 26, 2026Component Missing

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE HAD MISSING BONETTE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24700417 ↗
  • MalfunctionMar 24, 2026Degraded; Material Separation

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE EXHIBITED CHIPPED LENS AND EXTREMELY WORN DISTAL TIP. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24676918 ↗
  • MalfunctionMar 24, 2026Detachment of Device or Device Component

    NO ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24674916 ↗
  • MalfunctionMar 23, 2026Degraded

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE EXHIBITED EXTREMELY WORN DISTAL END. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24668198 ↗
  • MalfunctionMar 18, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE EXHIBITED BROKEN WINDSCREEN. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24628038 ↗
  • MalfunctionFeb 26, 2026Degraded

    IT WAS OBSERVED DURING THE DEVICE EVALUATION THAT THE RIGID ARTHROSCOPE HAD TIP COVER GLASS DAMAGE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24454676 ↗
  • MalfunctionFeb 20, 2026Unstable

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE EXHIBITED LOOSE COLOR RING. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24398697 ↗
  • MalfunctionFeb 17, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE EXHIBITED MISSING EYEPIECE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24365525 ↗
  • MalfunctionFeb 16, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE HAD A SCATTERED E/P LENS AND E/P COVER GLASS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24343925 ↗
  • MalfunctionFeb 4, 2026Break

    IT WAS REPORTED THAT THE RIGID SCOPE HAD A DISTAL LENS DAMAGED ON THE OUTSIDE DURING REPROCESSING. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24261990 ↗
  • MalfunctionJan 20, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE DISTAL END OF THE RIGID ARTHROSCOPE INSERTION TUBE WAS FOUND TO BE BROKEN. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24116222 ↗
  • MalfunctionJan 20, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THAT THE RIGID ARTHROSCOPE DISTAL END OF INSERTION TUBE WAS FOUND TO BE BROKEN. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24115397 ↗
  • MalfunctionJan 20, 2026Break

    IT WAS OBSERVED DURING THE DEVICE EVALUATION THAT THE RIGID ARTHROSCOPE HAD A BROKEN LIGHT EMISSION SURFACE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24115390 ↗
  • MalfunctionJan 13, 2026Break

    NO ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24058247 ↗
  • MalfunctionJan 9, 2026Crack

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE EXHIBITED A CRACKED OPTICAL SYSTEM LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24021260 ↗
  • MalfunctionJan 2, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ARTHROSCOPE HAD BROKEN LIGHT GUIDE FIBERS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23943368 ↗
  • MalfunctionDec 26, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS OBSERVED DURING THE DEVICE EVALUATION THAT THE RIGID ARTHROSCOPE EXHIBITED A DETACHED EYEPIECE FUNNEL. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23897662 ↗