Olympus WA64710ARecalls & reported problems

OLYMPUS Winter & Ibe GmbH · Jaws "HiQ+", 5 x 330 mm, needle holder, curved · Class 2

Adverse event reports
7
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 04042761031073), received between Aug 13, 2018 and Aug 27, 2026 — classified as 1 injury, 6 malfunctions.

The most frequently reported specific device problem is “Break” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break6
  • Detachment of Device or Device Component1
  • Fracture1
  • Loose or Intermittent Connection1
  • Material Fragmentation1
  • Mechanical Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 27, 2026Break

    It was reported that the reusable Suturing needle holder was delivered with a broken tip. The malfunction was identified during installation. There were no reports of patient involvement.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50483684 ↗
  • MalfunctionApr 30, 2026Break

    THE CUSTOMER DID NOT REPORT A MALFUNCTION. DURING ONSITE INSPECTION OF THE REUSABLE SUTURING NEEDLE HOLDER, BROKEN JAWS WERE FOUND. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25050606 ↗
  • MalfunctionMar 17, 2026Loose or Intermittent Connection

    IT WAS REPORTED THE SUTURING NEEDLE HOLDER IS LOOSE AND DOES NOT HOLD THE NEEDLE. THE ISSUE OCCURRED DURING INSPECTION FOR USE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24616853 ↗
  • MalfunctionMay 20, 2025Break; Break

    IT WAS REPORTED THE SUBJECT DEVICE'S NEEDLE HOLDER WAS NOT WORKING. THE JAW WAS NOT HOLDING PROPERLY DUE TO A BROKEN JAW HINGE. THE ISSUE OCCURRED AT SERVICE/MAINTENANCE, NOT IN A CLINICAL SETTING. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22055689 ↗
  • InjuryAug 6, 2024Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    IT WAS REPORTED, DURING A PROCEDURE. WHILE SUTURING, WITH THE NEEDLE HOLDER. A PIECE OF THE TIP FELL OFF, WHILE STILL IN THE PERITONEUM. AFTER RETRIEVING THE HAND INSTRUMENT, THE NURSE REALIZED, THAT THERE WAS A PIECE MISSING. AFTER THEY TRIED TO FIND THE PIECE INSIDE THE PATIENT AND DID NOT SUCCEED, THEY TOOK THE PATIENT OUT TO X-RAY. AFTER THEY FOUND WHERE THE TIP WAS, THEY MADE A REVISION AND TOOK IT OUT. THE PATIENT WAS REPORTED TO BE OKAY AND NOT IN A LIFE THREATENING CONDITION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19919150 ↗
  • MalfunctionApr 7, 2023Break; Break

    THE CUSTOMER REPORTED TO OLYMPUS, THE JAWS "HIQ+", 5 X 330 MM, NEEDLE HOLDER, CURVED WAS BROKEN. THE ISSUE WAS FOUND DURING RECEIPT INSPECTION. THE PROCEDURE WAS COMPLETED WITH A SIMILAR DEVICE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16701274 ↗
  • MalfunctionAug 13, 2018Break; Fracture; Material Fragmentation; Mechanical Problem; Break; Fracture; Material Fragmentation; Mechanical Problem

    OLYMPUS WAS INFORMED THAT DURING A THERAPEUTIC APPENDECTOMY PROCEDURE, THE JAWS OF THE NEEDLE HOLDER BROKE AND A FRAGMENT FELL INSIDE THE PATIENT'S BODY CAVITY. HOWEVER, NO FRAGMENT REMAINED INSIDE THE PATIENT SINCE IT WAS REPORTEDLY RETRIEVED. THE INTENDED PROCEDURE WAS SUCCESSFULLY COMPLETED USING A SIMILAR DEVICE AND THERE WAS NO REPORT ABOUT AN ADVERSE EVENT OR PATIENT INJURY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7776234 ↗

Other Mediastinoscope, Surgical devices

All Mediastinoscope, Surgical devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.