ELAN 4 GP176RRecalls & reported problems
Aesculap AG · ELAN 4 1-RING DIAMOND BURR X-COARSE D6.0 · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04046964558863), received between May 23, 2017 and May 23, 2017 — classified as 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Detachment of Device or Device Component1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 23, 2017Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED TO AESCULAP (B)(4) THAT AN ELAN 4 1-RING DIAMOND BURR X-COARSE D7.0 (PART # GP177R) (REF. ASSOCIATED MDR ID 2916714-2016-01047), AN ELAN 4 1-RING DIAMOND BURR X-COARSE D6.0 (PART # GP176R), AN ELAN 4 1-RING DIAMOND BURR COARSE D4.0 (PART # GP168R) (REF. ASSOCIATED MDR ID 2916714-2016-01049), AND AN ELAN 4 1-RING DIAMOND BURR COARSE D5.0 (PART # GP169R) (REF. ASSOCIATED MDR ID 2916714-2016-01050), WERE USED DURING AN EARS, NOSE AND THROAT (ENT) PROCEDURE. ACCORDING TO THE COMPLAINANT, DIAMOND GRAINS WERE OBSERVED FALLING FROM THE DEVICE BURRS INTO THE OPERATING AREA. THE SURGEON IMMEDIATELY OBSERVED THE GRAINS THROUGH THE MICROSCOPE AND REMOVED THEM FROM THE SITE. NO KNOWN PATIENT COMPLICATIONS OCCURRED AS A RESULT OF THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Known Impact Or Consequence To Patient
MAUDE report 6586458 ↗
Other DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) devices
- NA EMAX2PLUSSynthes GmbH · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)2,623 reports
- MIDAS REX MR8 MR8-AF02Medtronic Powered Surgical Solutions · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)952 reports
- Indigo™ 1845000Medtronic Xomed, Inc. · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)416 reports
- MIDAS REX MR8 MR8-AS07Medtronic Powered Surgical Solutions · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)232 reports
- MIDAS REX MR8 MR8-AA10Medtronic Powered Surgical Solutions · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)192 reports
- Midas Rex MR8 MR8-AF02Medtronic Powered Surgical Solutions · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)189 reports
- NA 5407-FA2-000Stryker Corporation · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)181 reports
- Indigo™ 1845000Medtronic Xomed, Inc. · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)165 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page