AESCULAP FH913BRecalls & reported problems

Aesculap AG · Rongeur detachable, 150 °, angled upwards, 7" (180 mm), smooth, jaw width: 3 mm, stainless steel · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04046964608414), received between Sep 1, 2020 and Sep 1, 2020 — classified as 1 malfunction.

The most frequently reported specific device problem is “Material Erosion” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Appropriate Device Problem Term/Code Not Available1
  • Material Erosion1
  • Peeled/Delaminated1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 1, 2020Material Erosion; Peeled/Delaminated; Appropriate Device Problem Term/Code Not Available; Material Erosion; Peeled/Delaminated; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT THERE WAS AN ISSUE WITH A RONGEUR. ACCORDING TO THE COMPLAINT DESCRIPTION THE SURFACE QUALITY CHANGED. AFTER 9 TIMES OF PREPARATION THE COATING DISSOLVES AND THE SURFACE CONDITION HAS CHANGED. THERE ARE ALSO UNEVENNESSES IN THE MATERIAL. FOUND PRIOR TO USE. THERE WAS NO PATIENT HARM. ADDITIONAL INFORMATION WAS NOT PROVIDED NOR AVAILABLE. THE MALFUNCTION IS FILED UNDER AAG REFERENCE (B)(4). ASSOCIATED MEDWATCH-REPORTS: 9610612-2020-00457 (B)(4), 9610612-2020-00459 (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions; No Consequences Or Impact To Patient

    MAUDE report 10480175 ↗

FDA clearance and classification

The FDA regulates product code HTX (rongeur) under 21 CFR 888.4540 as a Class I device. 21 CFR 888.4540 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the AESCULAP FH913B

Has the AESCULAP FH913B been recalled?

No FDA recall record in our data names this exact device identifier (DI 04046964608414), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the AESCULAP FH913B?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Sep 1, 2020. That report lists device problems “Material Erosion” (1) and “Peeled/Delaminated” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the AESCULAP FH913B?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the AESCULAP FH913B FDA approved?

Devices of this type (product code HTX) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Aesculap AG.

Who makes the AESCULAP FH913B, and is it still sold?

The FDA's device database lists Aesculap AG as the company responsible for it (brand AESCULAP, model FH913B). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other RONGEUR devices

All RONGEUR devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page