DIPLOMAT TulipRecalls & reported problems
SIGNUS Medizintechnik GmbH · The modular DIPLOMAT® pedicle screw system is a rod-screw system that firmly connects two or more screws via the screw head and a rod using a force-fit or form-fit connection. Additional fixation elements, such as cross bars, hooks, connectors and washers, can also be used. The DIPLOMAT® pedicle screw system is applied temporarily to provide internal posterior stabilization until bone fusion in the lumbar or thoracic spine has taken place. The surgeon makes the final decision as to the indwelling time of the implant in the patient‘s body and the time when the implant is to be explanted. The pedicle screw system is implanted from a posterior approach. The implant is screwed into the vertebral body via the pedicle and it can be applied in a single segment or multiple segments. Implantation is facilitated by use of the specially developed accessories for inserting and positioning the implants. Only these accessories ensure safe use. Our product information provides further system-related information on the surgical method. If there are any preoperative uncertainties relating to the implant, information must be obtained from SIGNUS. Instruments specially developed by SIGNUS to ensure safe application are available for use with the implant system. · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04047844020043), received between Mar 14, 2024 and Mar 14, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture1
Patient problems
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 14, 2024Fracture; Fracture
THE PATIENT WAS OPERATED WITH DIPLOMAT PEDICLE SCREW SYSTEM (B)(6) 2022, TWO LEVEL SURGERY L4- L5- S1. HE NOTICED SOME NOISE IN HIS BACK. A CHECK REVEALED BROKEN PEDICLE SCREWS WHICH WERE SURGICALLY REMOVED (B)(6) 2023. FRACTURE OF IMPLANT COMPONENTS IS A KNOWN RISK INDICATED IN THE IFU.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 18901899 ↗
Other Orthosis, Spondylolisthesis Spinal Fixation devices
- CD HORIZON® Spinal System 7540020Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation257 reports
- MANTIS Redux 48289999Stryker Corporation · Orthosis, spondylolisthesis spinal fixation76 reports
- EXPEDIUM TOP NOTCH 179771555Depuy Spine, LLC · Orthosis, spondylolisthesis spinal fixation41 reports
- EXPEDIUM 179712650Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation31 reports
- EXPEDIUM VERSE 199721530Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4 5 48130000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4.5 System - XIA CT 48850000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation27 reports
- CD HORIZON® Spinal System 7576545Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation26 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page