Skip to content

n.a. 26050XARecalls & reported problems

Karl Storz GmbH & Co. KG · Inner Sheath, rotatable, for 26050SL · Class 2

Adverse event reports
6
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 04048551092668), received between Aug 20, 2020 and Sep 2, 2026 — classified as 2 injuries, 4 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 2 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component3
  • Material Fragmentation2
  • Break1
  • Dent in Material1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Insufficient Information1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 2, 2026Detachment of Device or Device Component

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50571552 ↗
  • MalfunctionFeb 18, 2025Break; Dent in Material; Break; Dent in Material

    IT WAS REPORTED ON (B)(6) 2025 DURING A HYSTEROSCOPY PROCEDURE THE CERAMIC BEAK TIP OF 26FR INNERSHEATH BROKE OFF IN THE PATIENT. PIECE WAS RECOVERED. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21402237 ↗
  • InjuryNov 16, 2023Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT WHILE DOING A RESECTION UNDER A GYNAE LIST. WHERE THE KARL STORZ GYNAE RESECTOSCOPE SHEATH HAS MELTED AND THE CERAMIC BEAK HAS BROKEN. FORTUNATELY, THE PATIENT AND SAFE AND ALL DEBRIS WERE RETRIEVED INSIDE THE PATIENT'S CAVITY. IT WAS STATED THAT A MEDICAL/SURGICAL INTERVENTION WAS REQUIRED TO RETRIEVE THE BROKEN PARTS. NO DEATH OR (UNANTICIPATED) SERIOUS DETERIORATION IN STATE OF HEALTH REPORTED. DUE TO THE MEDICAL INTERVENTION, A REPORT IS REQUIRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18156275 ↗
  • InjuryNov 16, 2023Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT WHILE DOING A RESECTION UNDER A GYNAE LIST. WHERE THE KARL STORZ GYNAE RESECTOSCOPE SHEATH HAS MELTED AND THE CERAMIC BEAK HAS BROKEN. FORTUNATELY, THE PATIENT AND SAFE AND ALL DEBRIS WERE RETRIEVED INSIDE THE PATIENT'S CAVITY. IT WAS STATED THAT A MEDICAL/SURGICAL INTERVENTION WAS REQUIRED TO RETRIEVE THE BROKEN PARTS. NO DEATH OR (UNANTICIPATED) SERIOUS DETERIORATION IN STATE OF HEALTH REPORTED. DUE TO THE MEDICAL INTERVENTION, A REPORT IS REQUIRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18156272 ↗
  • MalfunctionDec 7, 2020Material Fragmentation; Material Fragmentation

    AS PER A MANUFACTURER INCIDENT REPORT WE RECEIVED FROM THE FACTORY IN (B)(6): TIP BROKE OFF; THE BROKEN PIECE WAS LEFT BEHIND IN PATIENT'S BODY.

    Patient problems: Insufficient Information

    MAUDE report 10963000 ↗
  • MalfunctionAug 20, 2020Material Fragmentation; Material Fragmentation

    AS PER A MANUFACTURER INCIDENT REPORT WE RECEIVED FROM THE FACTORY IN (B)(6): FOLLOWING INFORMATION IS PER FACILITY'S DESCRIPTION OF THE EVENT: DURING RESECTION OF A FIBROID, THE CERAMIC TIP OF THE RESECTOR BROKE OFF AND REMAINED IN THE UTERUS. THE DOCTOR SUCCEEDED IN RECOVERING 2 FRAGMENTS BUT WE CANNOT SAY THAT THERE IS NO MICRO-FRAGMENT LEFT THAT IS INVISIBLE IN ENDOSCOPY (HYSTEROSCOPY). IT WAS NECESSARY TO INCREASE THE DILATATION OF THE CERVIX TO RECOVER THE BROKEN PART. MOREOVER, WE HAD REACHED THE MAXIMUM NUMBER OF RE-INJECTION POCKETS ALLOWED DURING A HYSTEROSCOPY, SO THE PROCEDURE COULD NOT BE FINISHED AND THE PATIENT WILL PROBABLY HAVE TO BE TAKEN BACK TO THE OR. NO CLINICAL CONSEQUENCES NOTED AT THIS TIME.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 10432036 ↗

Other HYSTEROSCOPE (AND ACCESSORIES) devices

All HYSTEROSCOPE (AND ACCESSORIES) devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.