n.a. 26159GCRecalls & reported problems
Karl Storz GmbH & Co. KG · Bipolar Ballelectrode 5 Charr · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04048551094327), received between Jul 2, 2025 and Jul 2, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- Foreign Body In Patient1
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 2, 2025Break; Break
IT WAS REPORTED THAT DURING THE HYSTEROSCOPY, IN ORDER TO CUT OUT THE ENDOMETRIAL POLYP, THE TIP OF ELECTRODE EXPLODED INTO FEW PIECES INSIDE OF THE UTERUS. A MICROGRASPER WAS USED TO EVACUATE SOME OF THEM. BECAUSE OF PRESSURE OF LIQUID INSIDE OF THE UTERUS, THERE IS A CHANCE THAT SOME OF THE PIECES WENT THROUGH THE TUBES INTO THE DOUGLAS POUCH. IT WAS REPORTED THAT PATIENT HAS NO PROBLEMS AFTER SURGERY. AS IT CANNOT BE EXCLUDED THAT SOME PIECES REMAINED IN THE PATIENT'S BODY, THE CASE IS DEEMED PRECAUTIONARY REPORTABLE. NOTE: THE CUSTOMER DID NOT PROVIDE THE ARTICLE NUMBER OF THE AFFECTED DEVICE. IT WAS ONLY REPORTED THAT IT WAS A BIPOLAR BALL ELECTRODE 5 FR. WITHOUT FURTHER INFORMATION IT CANNOT BE DETERMINED WHICH IS THE EXACT ARTICLE AFFECTED AND IF IT WAS EVEN A KARL STORZ ARTICLE.
Patient problems: Foreign Body In Patient; Insufficient Information
MAUDE report 22387231 ↗
Other Laparoscope, general & plastic surgery devices
- HIGH DEFINITION LCD MONITOR OEV262HOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,937 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-12EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,886 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-10EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,086 reports
- Auto Suture OMS-T10BTCovidien LP · Laparoscope, general & plastic surgery1 recall955 reports
- PDB OMS-PDB1000Covidien LP · Laparoscope, general & plastic surgery859 reports
- VISERA 4K UHD CAMERA CONTROL UNIT OLYMPUS OTV-S400Olympus Medical Systems Corp. · Laparoscope, general & plastic surgery777 reports
- Auto Suture OMS-T10SBCovidien LP · Laparoscope, general & plastic surgery1 recall697 reports
- Spacemaker SMBTTRNDXCovidien LP · Laparoscope, general & plastic surgery590 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page