Skip to content

n.a. 26168DMRecalls & reported problems

Karl Storz GmbH & Co. KG · Anatomical Blade, medium · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04048551096154), received between Feb 1, 2024 and Feb 1, 2024 — classified as 2 injuries.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 2 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component2

Patient problems

  • Insufficient Information2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 1, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT THE MANIPULATOR RING BROKE OFF AND REMAINED IN THE VAGINA. THE PATIENT PASSED THE PART ON THE TOILET THE NEXT DAY. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED. NEVERTHELESS, THE RISK OF INTERNAL INJURIES AND INFECTION MUST BE TAKEN INTO ACCOUNT AS RELATED TO THIS INCIDENT.

    Patient problems: Insufficient Information

    MAUDE report 18624144 ↗
  • InjuryFeb 1, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT THE MANIPULATOR RING BROKE OFF AND REMAINED IN THE VAGINA. THE PATIENT PASSED THE PART ON THE TOILET THE NEXT DAY. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED. NEVERTHELESS, THE RISK OF INTERNAL INJURIES AND INFECTION MUST BE TAKEN INTO ACCOUNT AS RELATED TO THIS INCIDENT.

    Patient problems: Insufficient Information

    MAUDE report 18624143 ↗

Other HYSTEROSCOPE (AND ACCESSORIES) devices

All HYSTEROSCOPE (AND ACCESSORIES) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page