Karl Storz GmbH & Co. KG · CLICKLINE Forceps Insert · Class 2

Adverse event reports
9
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 04048551134108), received between Nov 4, 2024 and Sep 21, 2026 — classified as 6 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 4 reportsJun 2026: 0 reportsJul 2026: 2 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component4
  • Break2
  • Insufficient Device Problem Information2
  • Patient Device Interaction Problem2
  • Material Separation1

Patient problems

  • Laceration(s)4
  • No Clinical Signs, Symptoms or Conditions3
  • Foreign Body In Patient2

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 21, 2026Break

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50848637 ↗
  • InjuryJul 27, 2026Detachment of Device or Device Component

    It was reported that "There is a possibility that two lock pins from the product in question fell into the abdominal cavity. It is believed that they fell out when the omentum was grasped at the end of the surgery. An X-ray examination was performed, but the damaged area was not found. Another X-ray examination is scheduled."

    Patient problems: Foreign Body In Patient

    MAUDE report 50008551 ↗
  • InjuryJul 27, 2026Detachment of Device or Device Component

    It was reported that "There is a possibility that two lock pins from the product in question fell into the abdominal cavity. It is believed that they fell out when the omentum was grasped at the end of the surgery. An X-ray examination was performed, but the damaged area was not found. Another X-ray examination is scheduled."

    Patient problems: Foreign Body In Patient

    MAUDE report 50008328 ↗
  • InjuryMay 22, 2026Patient Device Interaction Problem

    IT WAS REPORTED WHILE USING THE 33310CC, THE DOCTOR TORE THE INTESTINE AND CAUSED BLEEDING WHEN GRASPING INTESTINAL TISSUE. INSTRUMENT INSPECTION REVEALED THAT THE PRODUCT SURFACE WAS ROUGH, WHICH IS PRONE TO CAUSING INTESTINAL TISSUE BLEEDING DURING GRASPING. FURTHERMORE IT WAS STATED IT IS INTESTINAL TISSUE INJURY. THE CLINICIAN BELIEVES THAT THE INJURY MAY ALSO BE RELATED TO THE PATIENT'S ADVANCED AGE AND FRAGILE INTESTINAL TISSUE, BUT THIS CANNOT BE CONFIRMED. MOREOVER, RC INSPECTION REVEALED THAT THE DEVICE SURFACE WAS NOT SIGNIFICANTLY ROUGH. THE SURGEON PROMPTLY PERFORMED SUTURING ON THE LACERATED BOWEL TISSUE.

    Patient problems: Laceration(s)

    MAUDE report 25260828 ↗
  • InjuryMay 22, 2026Patient Device Interaction Problem

    IT WAS REPORTED WHILE USING THE 33310CC, THE DOCTOR TORE THE INTESTINE AND CAUSED BLEEDING WHEN GRASPING INTESTINAL TISSUE. INSTRUMENT INSPECTION REVEALED THAT THE PRODUCT SURFACE WAS ROUGH, WHICH IS PRONE TO CAUSING INTESTINAL TISSUE BLEEDING DURING GRASPING. FURTHERMORE IT WAS STATED IT IS INTESTINAL TISSUE INJURY. THE CLINICIAN BELIEVES THAT THE INJURY MAY ALSO BE RELATED TO THE PATIENT'S ADVANCED AGE AND FRAGILE INTESTINAL TISSUE, BUT THIS CANNOT BE CONFIRMED. MOREOVER, RC INSPECTION REVEALED THAT THE DEVICE SURFACE WAS NOT SIGNIFICANTLY ROUGH. THE SURGEON PROMPTLY PERFORMED SUTURING ON THE LACERATED BOWEL TISSUE.

    Patient problems: Laceration(s)

    MAUDE report 25260825 ↗
  • InjuryMay 21, 2026Insufficient Device Problem Information

    THE FOLLOWING WAS REPORTED: "DURING A LAPAROSCOPIC GASTROINTESTINAL SURGERY, WHILE USING 33310CC, THE DOCTOR TORE THE GASTROINTESTINAL TRACT AND CAUSED BLEEDING WHEN GRASPING INTESTINAL TISSUE."

    Patient problems: Laceration(s)

    MAUDE report 25250249 ↗
  • InjuryMay 21, 2026Insufficient Device Problem Information

    THE FOLLOWING WAS REPORTED: "DURING A LAPAROSCOPIC GASTROINTESTINAL SURGERY, WHILE USING 33310CC, THE DOCTOR TORE THE GASTROINTESTINAL TRACT AND CAUSED BLEEDING WHEN GRASPING INTESTINAL TISSUE."

    Patient problems: Laceration(s)

    MAUDE report 25250246 ↗
  • MalfunctionMay 28, 2025Material Separation; Detachment of Device or Device Component; Material Separation; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING THE SURGICAL PROCEDURE, THE CURVED FENESTRATED CLAMP PRESENTED A PROBLEM, WHERE THE INTERNAL STEM CAME LOOSE FROM THE TUBE AFTER INSERTION INTO THE ABDOMINAL CAVITY. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22099012 ↗
  • MalfunctionNov 4, 2024Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    IT WAS REPORTED THAT THE TIP OF A LAPAROSCOPIC INSTRUMENT INSERT DROPPED DURING USE IN A LIVE PATIENT CASE. BROKEN TIP WAS IMMEDIATELY RECOVERED AND REMOVED FROM THE CAVITY; FAULTY INSTRUMENT WAS PUT ASIDE AND REPLACED WITH ANOTHER LAPAROSCOPIC INSTRUMENT.