Skip to content

CLICKLINE 33310KRecalls & reported problems

Karl Storz GmbH & Co. KG · Forceps Insert · Class 2

All models of CLICKLINE (46)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04048551134290), received between Apr 4, 2025 and Dec 23, 2025 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Sharp Edges” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 2 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Sharp Edges2
  • Mechanical Problem1

Patient problems

  • Liver Laceration(s)2
  • Gastrointestinal Hemorrhage1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 23, 2025Sharp Edges; Sharp Edges

    IT HAS BEEN REPORTED THE SURGEON HAD A SITUATION WHERE THE CUL-DE-SAC HAD A SIGNIFICANT AMOUNT OF BLOOD IN IT AND BLINDLY GRASPED THE BOWEL INSTEAD OF THE CYST THEY INTENDED TO RETRIEVE. THE SURGEON WAS SPECULATIVE THAT THE SHARP EDGE COULD HAVE CUT THE SEROSA. SINCE THE PATIENT GOT INJURED, THE CASE IS DEEMED AS REPORTABLE.

    Patient problems: Liver Laceration(s)

    MAUDE report 23879087 ↗
  • MalfunctionDec 23, 2025Sharp Edges; Sharp Edges

    IT HAS BEEN REPORTED THE SURGEON HAD A SITUATION WHERE THE CUL-DE-SAC HAD A SIGNIFICANT AMOUNT OF BLOOD IN IT AND BLINDLY GRASPED THE BOWEL INSTEAD OF THE CYST THEY INTENDED TO RETRIEVE. THE SURGEON WAS SPECULATIVE THAT THE SHARP EDGE COULD HAVE CUT THE SEROSA. SINCE THE PATIENT GOT INJURED, THE CASE IS DEEMED AS REPORTABLE.

    Patient problems: Liver Laceration(s)

    MAUDE report 23879085 ↗
  • InjuryApr 4, 2025Mechanical Problem; Mechanical Problem

    IT WAS REPORTED THAT THE SURGEON HAD A SITUATION WHERE THE GRASPER GOT STUCK IN THE OMENTUM AND IT TOOK SOME GENTLE DISSECTION TO GET IT OUT. THE SHARP CORNER WHERE THE GRASPER IS CONNECTS TO THE SHAFT IS WHAT WAS STUCK. THE SURGEON HAD A SITUATION WHERE THE GRASPER GOT STUCK IN THE OMENTUM AND IT TOOK SOME GENTLE DISSECTION TO GET IT OUT. THE SHARP CORNER WHERE THE GRASPER IS CONNECTS TO THE SHAFT IS WHAT WAS STUCK. SMALL EPIPLOICA SEROSAL INJURY AS IT WAS SNAGGED ON THE EPIPLOICA - HOWEVER, IF THIS HAPPENED ON THE BOWEL SEROSA, IT COULD CAUSE A PERFORATION/TEAR OF THE BOWEL, EXPECTANTLY MANAGED. DUE TO THE SMALL EPIPLOICA.

    Patient problems: Gastrointestinal Hemorrhage

    MAUDE report 21778479 ↗

Other Laparoscope, general & plastic surgery devices

All Laparoscope, general & plastic surgery devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page