CLICKLINE 33310ONRecalls & reported problems
Karl Storz GmbH & Co. KG · CLICKLINE Forceps Insert · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04048551134580), received between Jan 11, 2021 and Aug 31, 2022 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Insufficient Device Problem Information2
Patient problems
- Bowel Perforation1
- Foreign Body In Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryAug 31, 2022Insufficient Device Problem Information; Insufficient Device Problem Information
AS PER MANUFACTURER INCIDENT REPORT #(B)(4) RECEIVED FROM THE FACTORY IN (B)(6). IT WAS REPORTED THAT THERE WAS AN ISSUE WITH THE FORCEPS INSERT. ACCORDING TO THE COMPLAINT DESCRIPTION, THE DEVICE WAS USED DURING LAPAROSCOPIC CASE. WHILE IN USE, THE INSTRUMENT NICKED A SECTION OF THE BOWEL, CREATING A SMALL TEAR.
Patient problems: Bowel Perforation
MAUDE report 15330236 ↗MalfunctionJan 11, 2021Insufficient Device Problem Information; Insufficient Device Problem Information
AS PER A COPY OF A MIR WE RECEIVED FROM THE FACTORY IN (B)(6): THE INSTRUMENT HAS BEEN USED TO MOBILIZE THE UTERINE GRAFT. AT THE END OF THE OPERATION, A MILLIMETER PIECE OF THE DISTAL BRANCH OF THE FORCEPS IS MISSING, CONFIRMED WITH CONTROL X-RAY. THE PATIENT WAS INFORMED.
Patient problems: Foreign Body In Patient
MAUDE report 11151514 ↗
Other Laparoscope, general & plastic surgery devices
- HIGH DEFINITION LCD MONITOR OEV262HOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,937 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-12EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,886 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-10EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,086 reports
- Auto Suture OMS-T10BTCovidien LP · Laparoscope, general & plastic surgery1 recall955 reports
- PDB OMS-PDB1000Covidien LP · Laparoscope, general & plastic surgery859 reports
- VISERA 4K UHD CAMERA CONTROL UNIT OLYMPUS OTV-S400Olympus Medical Systems Corp. · Laparoscope, general & plastic surgery777 reports
- Auto Suture OMS-T10SBCovidien LP · Laparoscope, general & plastic surgery1 recall697 reports
- Spacemaker SMBTTRNDXCovidien LP · Laparoscope, general & plastic surgery590 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page