NA 26616ACARecalls & reported problems

Karl Storz GmbH & Co. KG · TIPCAM1 RUBINA 0°, OPAL1 NIR/ICG, 4K 3D · Class 2

Adverse event reports
10
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 04048551426180), received between Nov 5, 2025 and Sep 29, 2026 — classified as 10 malfunctions.

The most frequently reported specific device problem is “Display or Visual Feedback Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 2 reportsMar 2026: 1 reportsApr 2026: 2 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 2 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Display or Visual Feedback Problem3
  • Optical Distortion3
  • Poor Quality Image3
  • Insufficient Device Problem Information2
  • Unexpected Shutdown1

Patient problems

  • No Clinical Signs, Symptoms or Conditions10

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 29, 2026Poor Quality Image

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50936914 ↗
  • MalfunctionSep 23, 2026Unexpected Shutdown

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50876093 ↗
  • MalfunctionAug 20, 2026Poor Quality Image

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50354328 ↗
  • MalfunctionApr 14, 2026Display or Visual Feedback Problem

    IT WAS REPORTED THAT THE OPERATING ROOM TEAM INTERFACE (ORTI) SCREEN ON THE TOWER BEGAN FLICKERING AND BECAME FROZEN AFTER AN ENDOSCOPE ERROR MESSAGE WAS TRIGGERED. THE ISSUE WAS RESOLVED BY REPLACING THE ENDOSCOPE WITH A 30 DEGREE ENDOSCOPE. THERE WAS NO PATIENT INJURY. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24874687 ↗
  • MalfunctionApr 14, 2026Display or Visual Feedback Problem

    IT WAS REPORTED THAT THE OPERATING ROOM TEAM INTERFACE (ORTI) SCREEN ON THE TOWER BEGAN FLICKERING AND BECAME FROZEN AFTER AN ENDOSCOPE ERROR MESSAGE WAS TRIGGERED. THE ISSUE WAS RESOLVED BY REPLACING THE ENDOSCOPE WITH A 30 DEGREE ENDOSCOPE. THERE WAS NO PATIENT INJURY. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24873974 ↗
  • MalfunctionMar 20, 2026Optical Distortion

    IT WAS REPORTED THAT, DURING A ROBOTIC LAPAROSCOPIC PROCEDURE, THE ENDOSCOPE'S LENS WAS INFILTRATED, RESULTING IN A BLURRED FIELD OF VISION ON THE IMAGE. THERE WAS NO PATIENT INJURY. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24656030 ↗
  • MalfunctionFeb 16, 2026Optical Distortion

    IT WAS REPORTED THAT, DURING A ROBOTIC LAPAROSCOPIC PROSTATECTOMY, THE ENDOSCOPE'S IMAGE WAS BLURRED AND UNFOCUSED. IT WAS EXCHANGED WITH A NEW ENDOSCOPE AND THE PROCEDURE WAS COMPLETED WITHOUT FURTHER INCIDENT. THE EXCHANGE RESULTED IN A FIVE-MINUTE DELAY. THERE WAS NO PATIENT INJURY. CROSS REFERENCE MDR: 9610617-2026-00311.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24350023 ↗
  • MalfunctionFeb 16, 2026Optical Distortion

    IT WAS REPORTED THAT, DURING A ROBOTIC LAPAROSCOPIC PROSTATECTOMY, THE ENDOSCOPE'S IMAGE WAS BLURRED AND UNFOCUSED. IT WAS EXCHANGED WITH A NEW ENDOSCOPE AND THE PROCEDURE WAS COMPLETED WITHOUT FURTHER INCIDENT. THE EXCHANGE RESULTED IN A FIVE MINUTE DELAY. THERE WAS NO PATIENT INJURY. CROSS REFERENCE MDR: 9610617-2026-00310.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24350022 ↗
  • MalfunctionDec 23, 2025Poor Quality Image; Insufficient Device Problem Information; Poor Quality Image; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE ENDOSCOPE IMAGE WAS BLURRY DURING PROCEDURE. IT APPEARED AS IF THE AUTOFOCUS OF THE CAMERA WAS NOT PERFORMING WELL. EXTERNAL MONITORS SHOWED THE SAME BLUR. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23884892 ↗
  • MalfunctionNov 5, 2025Display or Visual Feedback Problem; Insufficient Device Problem Information; Display or Visual Feedback Problem; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE ENDOSCOPE CAMERA DID NOT FUNCTION AND THERE WAS NO IMAGE. A NEW ENDOSCOPE WAS REPLACED TO RESOLVE THE ISSUE. THERE WAS A 5-MINUTE DELAY. THERE WAS NO PATIENT INJURY. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23477135 ↗

Other Confocal optical imaging devices

All Confocal optical imaging devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.