Babyroo TN300 Infant Radiant Warmer MU20300Recalls & reported problems

Draeger Medical Systems, Inc. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04049098099042), received between May 30, 2024 and May 30, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Excessive Heating” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Excessive Heating1

Patient problems

  • Superficial (First Degree) Burn1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 30, 2024Adverse Event Without Identified Device or Use Problem; Excessive Heating; Adverse Event Without Identified Device or Use Problem; Excessive Heating

    THE CUSTOMER REPORTED THAT THE BABYROO WAS SET TO 36.9 CELSIUS WITH NO HUMIDIFIER, TO WARM THE BABY THAT HAD A SKIN TEMPERATURE OF 36.2°C. THE CUSTOMER REPORTED THAT BABY'S SKIN ON THE REAR OF THE THE THIGH WAS BURNT (RED SKIN), AND THAT THE DEVICE DID NOT TRIGGER ANY ALARM, AND THAT THE RADIAN WAS WARM. ADDITIONAL INFORMATION FROM THE CUSTOMER STATED THAT THE DEGREE WAS FIRST DEGREE, AND THAT THERE WAS A SLIGHT REDNESS PRESENT ON THE CALF THAT WENT AWAY WITHIN 30 MINUTES OF A COLD COMPRESS. THERE WAS NO OTHER FOLLOW UP AND NO BLISTERING. THE ADDITIONAL INFORMATION PROVIDED STATED THAT THE BABY WAS WITHIN HOURS OF BEING BORN, AND WEIGHED 2.340 KG. THE BABY WAS MOVED AWAY FROM THE RADIAN IN A LOCATION THAT KEPT THE BABY WARM BUT NOT DIRECTLY HEATED, AND A PEDIATRICIAN WAS CALLED IN. THE PATIENT WAS CONFIRMED TO BE IN GOOD CONDITION WITH NO REMAINING CONSEQUENCES. THE CUSTOMER CONFIRMED THAT THE PRE-USE CHECKOUT WAS PERFORMED, AND THAT THEY DID NOT USE A HEATED WARMER. A CENTRAL SKIN TEMPERATURE PROBE WAS POSITIONED ON THE ABDOMEN AND SECURED WITH A SUITABLE DEVICE. THE BABY HAD NO CLOTHING, JUST A NAPPY WITH A CAP OVER HIS HEAD.

    Patient problems: Superficial (First Degree) Burn

    MAUDE report 19430376 ↗