Skip to content

VISULAS VISULAS combiRecalls & reported problems

Carl Zeiss Meditec AG · VISULAS combi is intended for use in photocoagulating and photodisrupting ocular tissues in the treatment of diseases of the eye, including • Photocoagulation of the retina • Trabeculoplasty • Iridotomy • Posterior capsulotomy • Posterior membranectomy This device is Prescription Use (Rx) only. · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04049471091496), received between Nov 14, 2025 and Nov 14, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information1

Patient problems

  • Convulsion/Seizure1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 14, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT FOLLOWING A LASER TREATMENT WITH THE VISULAS COMBI ON A PATIENT IN CANADA, THE PATIENT APPARENTLY HAD A SEIZURE AND THE CLINIC CALLED A CODE BLUE. THE PATIENT HAS BEEN RELEASED; HOWEVER, NO ADDITIONAL INFORMATION HAS BEEN PROVIDED. NOTE: IN THE CONTEXT OF A HOSPITAL IN CANADA, "CODE BLUE" REFERS TO A MEDICAL EMERGENCY SITUATION WHERE A PATIENT IS EXPERIENCING CARDIAC ARREST OR RESPIRATORY FAILURE AND REQUIRES IMMEDIATE RESUSCITATION. THIS TERM IS PART OF A STANDARDIZED SET OF EMERGENCY CODES USED IN HOSPITALS TO QUICKLY COMMUNICATE SPECIFIC TYPES OF EMERGENCIES TO STAFF.

    Patient problems: Convulsion/Seizure

    MAUDE report 23560960 ↗

FDA clearance and classification

Cleared through 510(k) K233911 on Sep 6, 2024 (decision: Substantially Equivalent). Submitted by Carl Zeiss Meditec, AG as “VISULAS combi”. The FDA review took 269 days. FDA record ↗

The FDA regulates product code HQF (laser, ophthalmic) under 21 CFR 886.4390 as a Class II device. 21 CFR 886.4390 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the VISULAS VISULAS combi

Has the VISULAS VISULAS combi been recalled?

No FDA recall record in our data names this exact device identifier (DI 04049471091496), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the VISULAS VISULAS combi?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Nov 14, 2025. That report lists patient problem “Convulsion/Seizure” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the VISULAS VISULAS combi?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the VISULAS VISULAS combi FDA approved?

It was cleared through 510(k) K233911 on Sep 6, 2024. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the VISULAS VISULAS combi, and is it still sold?

The FDA's device database lists Carl Zeiss Meditec AG as the company responsible for it (brand VISULAS, model VISULAS combi). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Laser, Ophthalmic devices

All Laser, Ophthalmic devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page