uCentum™ comprehensive posterior system CS 3802-055-040Recalls & reported problems
Ulrich GmbH & Co. KG · Screw, polyaxial, Ø 5.5 mm, length 40 mm perforated · Class 2 · Implant
All models of uCentum comprehensive posterior system (15)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 6
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 04052536078769), received between Jan 8, 2021 and Jan 3, 2025 — classified as 6 injuries.
The most frequently reported specific device problem is “Fracture” (4 reports).
1 other recall cover devices cleared under the same FDA submission (K123717); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture4
- Detachment of Device or Device Component2
Patient problems
- Failure of Implant6
- Inadequate Osseointegration4
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
InjuryJan 3, 2025Fracture; Fracture
ACCORDING TO USER INFORMATION, A PEDICLE SCREW BROKE AFTER APPROXIMATELY 18 TO 24 MONTHS OF IMPLANTATION. NO FURTHER INFORMATION IS AVAILABLE AT THIS TIME.
Patient problems: Failure of Implant; Inadequate Osseointegration
MAUDE report 21072197 ↗InjuryJan 3, 2025Fracture; Fracture
ACCORDING TO USER INFORMATION. A PEDICLE SCREW BROKE AFTER APPROXIMATELY 18 TO 24 MONTHS OF IMPLANTATION. NO FURTHER INFORMATION IS AVAILABLE AT THIS TIME.
Patient problems: Failure of Implant; Inadequate Osseointegration
MAUDE report 21072057 ↗InjuryJan 3, 2025Fracture; Fracture
ACCORDING TO USER INFORMATION, A PEDICLE SCREW BROKE AFTER APPROXIMATELY 18 TO 24 MONTHS OF IMPLANTATION. NO FURTHER INFORMATION IS AVAILABLE AT THIS TIME.
Patient problems: Failure of Implant; Inadequate Osseointegration
MAUDE report 21069225 ↗InjuryJan 3, 2025Fracture; Fracture
ACCORDING TO USER INFORMATION. A PEDICLE SCREW BROKE AFTER APPROXIMATELY 18 TO 24 MONTHS OF IMPLANTATION. NO FURTHER INFORMATION IS AVAILABLE AT THIS TIME.
Patient problems: Failure of Implant; Inadequate Osseointegration
MAUDE report 21068841 ↗InjuryJan 8, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
SCREW CLAMPING PLATE DISASSOCIATED FROM SCREW DURING SURGERY. SCREW WAS REMOVED AND REPLACED.
Patient problems: Failure of Implant
MAUDE report 11140327 ↗InjuryJan 8, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
SCREW CLAMPING PLATE DISASSOCIATED FROM SCREW DURING SURGERY. SCREW WAS REMOVED AND REPLACED.
Patient problems: Failure of Implant
MAUDE report 11140325 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K123717. One submission often covers many models, so check the product and lot details in each record.
- Z-1126-2019 · Mar 8, 2019 · TerminatedULRICH Torque Limiting Handle for use with a Set Screw Driver to perform the final tightening of set screws in a spinal implant construct.
Other Orthosis, spondylolisthesis spinal fixation devices
- CD HORIZON® Spinal System 7540020Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation257 reports
- MANTIS Redux 48289999Stryker Corporation · Orthosis, spondylolisthesis spinal fixation76 reports
- EXPEDIUM TOP NOTCH 179771555Depuy Spine, LLC · Orthosis, spondylolisthesis spinal fixation41 reports
- EXPEDIUM 179712650Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation31 reports
- EXPEDIUM VERSE 199721530Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4 5 48130000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4.5 System - XIA CT 48850000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation27 reports
- CD HORIZON® Spinal System 7576545Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation26 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page