PANOVIEW PLUS HD 892109205Recalls & reported problems
Richard Wolf GmbH · DISCOSCOPE 20° Ø 9.3MM SL 177MM rigid, with lateral ocular lens, working channel Ø 5.6mm, irrigation channel Ø 2x 1.4mm, TL 293mm, rod lens system · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 04055207035115), received between Dec 20, 2018 and Oct 4, 2022 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Leak/Splash” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Leak/Splash4
- Optical Obstruction4
- Optical Problem1
- Poor Quality Image1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 4, 2022Leak/Splash; Optical Obstruction; Leak/Splash; Optical Obstruction
RWMIC REFERENCE COMPLAINT NO. (B)(4). ON (B)(6) 2022, IT WAS REPORTED TO RICHARD WOLF MEDICAL INSTRUMENTS CORP. (RWMIC) BY A USER FACILITY REPRESENTATIVE REGARDING PRODUCT ID# 892109205, (B)(4). "THIS NEWLY RECEIVED REPAIR EXCHANGE SCOPE LEAKS IRRIGATION AROUND THE FORWARD SEAL." ADDITIONAL INFORMATION REPORTED BY THE USER FACILITY REPRESENTATIVE: (EMAIL, DATED (B)(6) 2022) THIS ISSUE WAS DISCOVERED IN THE OPERATING ROOM. THE SCOPE WAS LEAKING IRRIGATION FLUID FROM THE REAR SEAL AT ALL PRESSURE LEVELS, SUCH THAT THE SET IRRIGATION PRESSURE COULD NOT BE MAINTAINED EVEN WITH EXCESSIVE FLOW. THIS RESULTED IN POOR SURGICAL VISIBILITY AND CONSUMPTION OF 36 LITERS OF IRRIGATION ON A CASE THAT WOULD NORMALLY TAKE 12-15 LITERS. CASE WAS COMPLETED AND THERE WAS NO PATIENT INJURY AS A RESULT." COMPLAINT DATA COLLECTION QUESTIONNAIRE REPAIR CUSTOMER SERVICE: WILL THE DEVICE BE RETURNED? YES. WAS THE DEVICE BEING USED ON A PATIENT WHEN THE REPORTING ISSUE OCCURRED? YES. WAS THERE ANY INJURY OR ILLNESS TO THE PATIENT DUE TO THE REPORTED ISSUE? NO. WAS THERE ANY INJURY OR ILLNESS TO ANY OTHER PERSONNEL DUE TO THE REPORTED ISSUE? NO. DID THE ISSUE CAUSE A DELAY IN THE PROCEDURE BEING PERFORMED? Y
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15540234 ↗MalfunctionOct 4, 2022Leak/Splash; Optical Obstruction; Leak/Splash; Optical Obstruction
RWMIC REFERENCE COMPLAINT NO. (B)(4). ON (B)(6) 2022, IT WAS REPORTED TO RICHARD WOLF MEDICAL INSTRUMENTS CORP. (RWMIC) BY A USER FACILITY REPRESENTATIVE REGARDING PRODUCT ID# 892109205, (B)(4). "THIS NEWLY RECEIVED REPAIR EXCHANGE SCOPE LEAKS IRRIGATION AROUND THE FORWARD SEAL." ADDITIONAL INFORMATION REPORTED BY THE USER FACILITY REPRESENTATIVE: (EMAIL, DATED SEPTEMBER 19, 2022) THIS ISSUE WAS DISCOVERED IN THE OPERATING ROOM. THE SCOPE WAS LEAKING IRRIGATION FLUID FROM THE REAR SEAL AT ALL PRESSURE LEVELS, SUCH THAT THE SET IRRIGATION PRESSURE COULD NOT BE MAINTAINED EVEN WITH EXCESSIVE FLOW. THIS RESULTED IN POOR SURGICAL VISIBILITY AND CONSUMPTION OF 36 LITERS OF IRRIGATION ON A CASE THAT WOULD NORMALLY TAKE 12-15 LITERS. THE CASE WAS COMPLETED AND THERE WAS NO PATIENT INJURY AS A RESULT." WILL THE DEVICE BE RETURNED? YES. WAS THE DEVICE BEING USED ON A PATIENT WHEN THE REPORTING ISSUE OCCURRED? YES. WAS THERE ANY INJURY OR ILLNESS TO THE PATIENT DUE TO THE REPORTED ISSUE? NO WAS THERE ANY INJURY OR ILLNESS TO ANY OTHER PERSONNEL DUE TO THE REPORTED ISSUE? NO DID THE ISSUE CAUSE A DELAY IN THE PROCEDURE BEING PERFORMED? YES. DID THE DELAY PUT THE PATIENT AT RISK? NO. WAS THERE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15540214 ↗MalfunctionOct 4, 2022Leak/Splash; Optical Obstruction; Leak/Splash; Optical Obstruction
RWMIC REFERENCE COMPLAINT NO. (B)(4). ON (B)(6) 2022, IT WAS REPORTED TO RICHARD WOLF MEDICAL INSTRUMENTS CORP. (RWMIC) BY A USER FACILITY REPRESENTATIVE REGARDING PRODUCT ID# 892109205, (B)(4). "THIS NEWLY RECEIVED REPAIR EXCHANGE SCOPE LEAKS IRRIGATION AROUND THE FORWARD SEAL." ADDITIONAL INFORMATION REPORTED BY THE USER FACILITY REPRESENTATIVE: (EMAIL, DATED (B)(6) 2022) THIS ISSUE WAS DISCOVERED IN THE OPERATING ROOM. THE SCOPE WAS LEAKING IRRIGATION FLUID FROM THE REAR SEAL AT ALL PRESSURE LEVELS, SUCH THAT THE SET IRRIGATION PRESSURE COULD NOT BE MAINTAINED EVEN WITH EXCESSIVE FLOW. THIS RESULTED IN POOR SURGICAL VISIBILITY AND CONSUMPTION OF 36 LITERS OF IRRIGATION ON A CASE THAT WOULD NORMALLY TAKE 12-15 LITERS. THE CASE WAS COMPLETED AND THERE WAS NO PATIENT INJURY AS A RESULT." WILL THE DEVICE BE RETURNED? YES. WAS THE DEVICE BEING USED ON A PATIENT WHEN THE REPORTING ISSUE OCCURRED? YES. WAS THERE ANY INJURY OR ILLNESS TO THE PATIENT DUE TO THE REPORTED ISSUE? NO. WAS THERE ANY INJURY OR ILLNESS TO ANY OTHER PERSONNEL DUE TO THE REPORTED ISSUE? NO. DID THE ISSUE CAUSE A DELAY IN THE PROCEDURE BEING PERFORMED? YES. DID THE DELAY PUT THE PATIENT AT RISK? NO. WAS THERE A SI
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15540123 ↗MalfunctionOct 4, 2022Leak/Splash; Optical Obstruction; Leak/Splash; Optical Obstruction
RWMIC REFERENCE COMPLAINT NO. (B)(4). THE PURPOSE OF THIS SUBMISSION IS TO REPORT THE RESULTS OF THE DEVICE INVESTIGATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15540108 ↗MalfunctionDec 20, 2018Poor Quality Image; Optical Problem; Poor Quality Image; Optical Problem
FOLLOW UP #1 TO PROVIDE INVESTIGATION RESULTS TO FDA. USER FACILITY RETURNED THE DEVICE TO RWMIC ON DECEMBER 05, 2018, AND WAS SENT TO THE MANUFACTURER FOR EVALUATION. THE EVALUATION WAS COMPLETED ON JANUARY 25, 2019. THE DEVICE APPEARED TO BE USED - THERE WAS MOISTURE IN THE OPTICAL SYSTEM AND NO LEAKAGE ON THE OPTIC COULD BE FOUND. THE REPORTED CONDITION WAS VERIFIED USING VISUAL AND FUNCTIONAL TESTING. THERE WERE NO SIGNS OF FALSE HANDLING BY THE USER. AS NO LEAKAGE ON THE OPTIC COULD BE FOUND, IT WAS UNCLEAR HOW THE MOISTURE COULD PENETRATE INTO THE OPTICAL SYSTEM. THE INSTRUMENT DID NOT MEET SPECIFICATIONS AND A MANUFACTURING DEFECT WAS NOT IDENTIFIED. THE INSTRUMENT WAS REPAIRED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8187144 ↗
FDA clearance and classification
The FDA regulates product code HRX (arthroscope) under 21 CFR 888.1100 as a Class II device. 21 CFR 888.1100 ↗
Devices of this type normally need 510(k) clearance before sale.
Common questions about the PANOVIEW PLUS HD 892109205
Has the PANOVIEW PLUS HD 892109205 been recalled?
No FDA recall record in our data names this exact device identifier (DI 04055207035115), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the PANOVIEW PLUS HD 892109205?
The FDA's MAUDE database lists 5 adverse event reports for this device, received between Dec 20, 2018 and Oct 4, 2022. In those reports, the most common specific device problems are “Leak/Splash” (4), “Optical Obstruction” (4) and “Optical Problem” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the PANOVIEW PLUS HD 892109205?
None of the reports are classified as deaths, 0 as injuries and 5 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the PANOVIEW PLUS HD 892109205, and is it still sold?
The FDA's device database lists Richard Wolf GmbH as the company responsible for it (brand PANOVIEW PLUS HD, model 892109205). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other ARTHROSCOPE devices
- FMS 283512Medos International Sàrl · ARTHROSCOPE1,791 reports
- Arthrex® AR-6480Arthrex, Inc. · ARTHROSCOPE925 reports
- FMS VUE 284002Depuy Mitek, LLC · ARTHROSCOPE814 reports
- MITEK 242018Medos International Sàrl · Arthroscope729 reports
- METRx® System 9560100Medtronic Sofamor Danek, Inc. · Arthroscope655 reports
- FMS VUE II 284004Medos International Sàrl · Arthroscope547 reports
- VAPR COOLPULSE 228146Depuy Mitek, LLC · ARTHROSCOPE468 reports
- FMS DUO 284580Depuy Mitek, LLC · ARTHROSCOPE458 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page