ExacTrac Dynamic 2.0Recalls & reported problems

Brainlab SE · Class 2

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04056481144609), received between Jan 16, 2026 and Jan 16, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Use of Device Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Use of Device Problem1

Patient problems

  • Unintended Radiation Exposure1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 16, 2026Use of Device Problem

    AN SBRT TREATMENT ON THE LIVER WAS PERFORMED USING A NON-BRAINLAB CBCT POSITIONING SYSTEM TOGETHER WITH THE EXACTRAC DYNAMIC 2.0 SYSTEM (ETD), USING ONLY SURFACE MONITORING CAPABILITIES. FOR THE PREPOSITIONING A TREATMENT BEAM WAS LOADED ON THE NON-BRAINLAB LINAR ACCELERATOR (LINAC) AND THE PREPOSITIONING WAS PERFORMED WITH EXACTRAC DYNAMIC 2.0. AFTER COMPLETING THE PREPOSITIONING, THE USER ACTIVELY CONFIRMED BY PRESSING THE "POSITIONING FINISHED" BUTTON INSIDE THE ETD SYSTEM, THAT THE PATIENT POSITIONING WITH A NON-BRAINLAB POSITIONING SYSTEM (CBCT) WAS COMPLETED, DESPITE IT WAS NOT PERFORMED YET. IN A SECOND STEP THE USER INADVERTENTLY ACTIVATED THE RADIATION BEAM AT THE NON-BRAINLAB LINAC, INSTEAD OF LOADING THE CBCT SETUP FIELD. THE USER IMMEDIATELY RECOGNIZED THE MISTAKE AND TURNED OFF THE BEAM. 50,8MU OF 3076.5MU (1 OUT OF 5 FRACTIONS) WERE DELIVERED TO THIS INITIAL POSITION, WHICH WAS 19,1 MM AWAY FROM THE ACTUAL TREATMENT POSITION. ACCORDING TO THE TREATING CLINICIAN, THE AMOUNT OF RADIATION TREATMENT DOSE DELIVERED TO A DIFFERENT LOCATION THAN INTENDED AS WELL AS THE DOSE DEVIATION TO THE PLANNED TARGET, CAN BE CONSIDERED NEGLECTABLE COMPARED TO THE OVERALL FRACTIONATED TR

    Patient problems: Unintended Radiation Exposure

    MAUDE report 24092782 ↗

Other Accelerator, Linear, Medical devices