Catapult Guide Sheath 5F, 60cm, straight, hydrophilic coatedRecalls & reported problems

Contract Medical International GmbH · Introducer Sheath System containing One (1) introducer Sheath with haemostasis valve and One (1) dilator. Introducer Sheath is hydrophilic coated on the distal end. · Class 2

All models of Catapult Guide Sheath (8)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04251244502065), received between Oct 22, 2025 and Oct 22, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1

Patient problems

  • Hemorrhage/Blood Loss/Bleeding1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 22, 2025Break; Break

    THE PROBLEM IS DESCRIBED AS FOLLOWED: STANDARD LE ANGIOGRAM. 5FR CATAPULT INSERTED EASILY INTO PATIENT. DR. WENT IN WITH SERRENATOR CUTTING BALLOON AND AS THEY REMOVED IT THE BRAIDING OF THE SHEATH STARTED TO COME APART AS VISUALIZED UNDER FLURO. DR. HAD TO PARTIALLY REMOVE SHEATH AND GO BACK IN TO RETRIEVE THE REST OF THE SHEATH BRAIDING THAT WAS STILL IN THE BODY. PATIENT HAD SOME BLOOD LOSS BUT IS FULLY RECOVERED AND HOME. WHAT TROUBLESHOOTING STEPS TOOK PLACE? WHAT TROUBLESHOOTING STEPS, IF ANY, RESOLVED THE ISSUE: REMOVAL OF SHEATH . WHAT IS THE NEXT COURSE OF ACTION? REPLACE PRODUCT PATIENT PRESENT AT TIME OF EVENT? YES PATIENT COMPLICATIONS: BLEEDING, BLOOD LOSS / HEMORRHAGE IN THE PHYSICIAN'S OPINION, DID THE DEVICE OR PROCEDURE CAUSE OR CONTRIBUTE TO THE PATIENT COMPLICATION? YES PLEASE DESCRIBE THE WAY IN WHICH THE DEVICE OR PROCEDURE CAUSED OR CONTRIBUTED TO THE PATIENT COMPLICATION? DEVICE BROKE IN PATIENT BODY- IT WAS FULLY REMOVED, BUT TOOK TIME AND CREATED SOME BLOOD LOSS MEDICAL OR SURGICAL INTERVENTIONS: REMOVAL OF SHEATH PATIENT ADMITTED TO HOSPITAL BEYOND THE STANDARD OF CARE: NO PATIENT OUTCOME: FULLY RECOVERED. AS REPORTED DEVICE CODES: 1188: DETACHMENT OF DEVI

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 23355600 ↗