ROTEM® ex-tem®Recalls & reported problems
Tem Innovations GmbH · The EXTEM assay is a semi-quantitative in vitro diagnostic assay used to monitor the coagulation process via the extrinsic pathway in citrated whole blood specimens on the ROTEM® delta. Clotting characteristics are described by the functional parameters Clotting Time (CT), Speed of Clot Formation (CFT and alpha angle), Clot Firmness (A20/MCF) and Clot Lysis (LOT, ML, LI(x)). CFT and alpha (Speed of Clot Formation) are complementary parameters and should be used in conjunction with the main parameters Clotting Time (CT) and Clot Firmness (A20/MCF). · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04260160470242), received between Jun 21, 2018 and Jun 21, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Output Problem” (1 report).
5 other recalls cover devices cleared under the same FDA submission (K101533); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Output Problem1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 21, 2018Output Problem; Output Problem
CUSTOMER REPORTED SEEING EXTENDED EX-TEM CT'S ON THEIR ROTEM DELTA INSTRUMENT WITH PATIENT RESULT ON NEW REAGENT LOT. THE CUSTOMER REPORTS THAT TWO PATIENTS WERE POSSIBLY INAPPROPRIATELY TRANSFUSED FRESH FROZEN PLASMA (FFP) DUE TO ERRONEOUS EX-TEM CT VALUES. THE CUSTOMER DID NOT REPORT AN ADVERSE EVENT FROM THE TRANSFUSIONS.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7625899 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K101533. One submission often covers many models, so check the product and lot details in each record.
- Z-2486-2019 · Jul 23, 2019 · TerminatedROTEM ex-tem Canada Part No: 503-05-CA
- Z-2485-2019 · Jul 23, 2019 · TerminatedROTEM ex-tem; US Part No: 503-05-US
- Z-2487-2019 · Jul 23, 2019 · TerminatedROTEM ex-tem Rest of the world part No: 503-05 (ROW)
- Z-0302-2017 · Sep 13, 2016 · Terminatedex-TEM Assay for ROTEM delta Thromboelastometry System. Art. no.: 503-05 US, ex-tem. Used to monitor the coagulation process via the extrinsic pathway in citrated whole blood spe
- Z-1379-2015 · Oct 23, 2014 · TerminatedROTROL P Control for ROTEM delta Thromboelastometry System, Manufactured for: Tem Innovations GmbH.
Other System, Multipurpose For In Vitro Coagulation Studies devices
- ACL TOP 970 CL 00000280097Instrumentation Laboratory Company · System, Multipurpose For In Vitro Coagulation Studies2 recalls0 reports
- TEG5000 HEMOSTASIS ANALYZER 07-022Haemonetics Corporation · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall2 reports
- STA Satellite® 58104Diagnostica Stago · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall1 report
- ACL ELITE PRO 00001000311RInstrumentation Laboratory Company · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall0 reports
- ACL ELITE PRO 00001000311Instrumentation Laboratory Company · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall0 reports
- ACL ELITE 00000880311RInstrumentation Laboratory Company · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall0 reports
- ACL ELITE 00000880311Instrumentation Laboratory Company · SYSTEM, MULTIPURPOSE FOR IN VITRO COAGULATION STUDIES1 recall0 reports
- Hemochron Whole Blood Microcoagulation System ELITEAccriva Diagnostics Holdings, Inc. · System, Multipurpose For In Vitro Coagulation Studies2 deaths13 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page