Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04546540089724), received between Apr 26, 2024 and Jan 20, 2026 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Difficult to Remove” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Difficult to Remove2
- Break1
- Fracture1
Patient problems
- Foreign Body In Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJan 20, 2026Difficult to Remove
IT WAS REPORTED THAT DURING THE EXTRACTION OF ASNIS 4.0, THE EXTRACTION PROVED DIFFICULT DUE TO THE BONE QUALITY BEING FAVOURABLE. UPON USING THE EXTRACTOR, THE TIP OF THE EXTRACTOR BROKE OFF. THE ASINIS 4.0 COULD NOT BE REMOVED AND REMAINS IMPLANTED IN THE BODY. IT IS NOTED THAT FRAGMENTS REMAIN WITHIN THE BODY. THE PHYSICIAN BELIEVES THESE FRAGMENTS CAN BE REMOVED DURING THE ATTEMPTED RE-EXTRACTION OF THE ASNIS.
Patient problems: Foreign Body In Patient
MAUDE report 24115663 ↗MalfunctionApr 26, 2024Break; Fracture; Difficult to Remove; Break; Fracture; Difficult to Remove
AS REPORTED: "PRIMARY SURGERY WAS PERFORMED ON (B)(6) 2023. REVISION SURGERY FOR REMOVE THE IMPLANTS DUE TO BONE UNION COMPLETED ON (B)(6) 2024. DURING PROCEDURE, SCREW AND EXTRACTOR WAS FRACTURED AND REMAINED IN THE PATIENT BODY. THE SURGEON DECIDE TO REMAIN THESE PIECES IN THE PATIENT, PROCEDURE WAS COMPLETED."
Patient problems: Foreign Body In Patient
MAUDE report 19197477 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page