NA 702624Recalls & reported problems
Stryker GmbH · Extractor · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04546540112873), received between Oct 4, 2021 and Nov 30, 2022 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Device Difficult to Setup or Prepare1
- Difficult to Remove1
- Fracture1
Patient problems
- Insufficient Information2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 30, 2022Break; Fracture; Break; Fracture
IT WAS REPORTED THAT DURING THE PROCEDURE THE KEY BROKE WHEN TRYING TO REMOVE IT FROM THE SCREW INSIDE THE PATIENT. NO ADDITIONAL INFORMATION IS AVAILABLE REGARDING IF ANY DEBRIS WAS LEFT BEHIND IN THE PATIENT.
Patient problems: Insufficient Information
MAUDE report 15886400 ↗MalfunctionOct 4, 2021Device Difficult to Setup or Prepare; Difficult to Remove; Device Difficult to Setup or Prepare; Difficult to Remove
IT WAS REPORTED THAT ON (B)(6) 2020 AN EXPLANTATION WAS PERFORMED ON A PATIENT WHO UNDERWENT OSTEOSYNTHESIS WITH 3 AZNIS 6.5MM. THE SURGEON ATTEMPTED TO REMOVE THE SCREW WITH A SPECIAL SCREWDRIVER, BUT THE SCREWDRIVER WOULDN'T TURN BECAUSE THE PATIENT'S BONE QUALITY WAS GOOD. TWO SCREWS WERE REMOVED, BUT ONE COULD NOT BE REMOVED AND REMAINED IN THE BODY. THE SURGEON ATTEMPTED TO REMOVE THE SCREW WITH ANOTHER INSTRUMENT; HOWEVER IT COULD NOT BE REMOVED.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 12568349 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗