NA 0226-3000Recalls & reported problems
Stryker GmbH · Flexible Shaft · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540145550), received between Oct 10, 2022 and Oct 10, 2022 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Fracture1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 10, 2022Break; Fracture; Break; Fracture
IT WAS REPORTED THAT : "BREAKAGE OF THE REAMER STRYKER ADAPTOR IN INTRAOPERATIVE WITH THE REAMER HEAD REMAINING IN THE PATIENT'S BONE." ACTION TAKEN : REMOVE THE ALESOR INTRODUCED INTO THE FEMUR. CUSTOMER REPORTED THAT: "INCIDENTAL DESCRIPTION: DURING A FEMUR NAILING PROCEDURE, THE MOTOR ADAPTER OF THE STRYKER REAMER BROKE WHILE THE SURGEON WAS USING IT ON THE PATIENT." CLINICAL CONSEQUENCES FOUND: ACTIVITY PERFORMED WITH A LOSS OF TIME AND/OR QUALITY CONSERVATIVE MEASURES AND ACTIONS TAKEN: REMOVE THE REAMER INSERTED IN THE FEMUR + THE GUIDE PIN WHICH WERE NO LONGER ATTACHED TO THE MOTOR ADAPTER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15569224 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page