NA 1806-0050Recalls & reported problems
Stryker GmbH · K-Wire · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540195845), received between Jun 20, 2019 and Jun 20, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Difficult to Remove” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Difficult to Remove1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 20, 2019Difficult to Remove
DURING HIP OSTEOSYNTHESIS SURGERY, THE 3 X 285MM KIRSCHENER NAIL REMAINED INSIDE THE FEMORAL CANAL AND IT WAS NOT POSSIBLE TO REMOVE IT, WHICH IS WHY IT REMAINS INSIDE THE PATIENT. ADDITIONAL INFORMATION: PART NUMBER 18060050 IS INSIDE THE PATIENT AND IT IS NOT BROKEN. THE K-WIRE REMAINS INSIDE THE PATIENT'S BONE. THE GAMMA3 TI NAIL WAS IMPLANTED ACCORDING TO THE TECHNIQUE THAT APPEARS IN THE CATALOG AND THE SURGEON ALWAYS PERFORMS BUT THIS WAS THE FIRST TIME THIS PROBLEM HAPPENED. THE EVENT OCCURRED DURING PRIMARY SURGERY WHICH LED TO 40 MINUTES DELAY WITHOUT ANY PATIENT IMPACT. DOCTOR DECIDE TO FINISH THE SURGERY WITH 18060050 INSIDE. DOCTOR TRIED TO REMOVE IT AT THE TIME OF THE SURGERY WITHOUT SUCCESS. BY THE END HE DECIDED TO KEEP IT INSIDE THE BONE AND HE MENTIONED HE BELIEVES IT WOULD AFFECT THE PATIENT.
Patient problems: Foreign Body In Patient
MAUDE report 8716033 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page