PROFYLE 57-13150Recalls & reported problems
Stryker GmbH · L-COMPRESSION PLATE,T-SHAPE,OBLIQUE,RI · Class 2 · Implant
All models of PROFYLE (21)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540243201), received between Dec 16, 2021 and Dec 16, 2021 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Fracture1
Patient problems
- Failure of Implant1
- Implant Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryDec 16, 2021Break; Fracture; Break; Fracture
AS REPORTED: "ON (B)(6)2020, THE PATIENT WAS ADMITTED TO THE HOSPITAL DUE TO FRACTURE OF THE FIRST TOE BONE. ON (B)(6),2020, THE PATIENT WAS TREATED WITH PLATE COMBINED WITH KIRSCHNER WIRE INTERNAL FIXATION, AND WAS DISCHARGED AFTER IMPROVEMENT. THE DOCTOR ORDERED REGULAR REVIEW IN THE OUTPATIENT DEPARTMENT. ON (B)(6) 2021, THE PATIENT CAME TO THE OUTPATIENT DEPARTMENT OF OUR HOSPITAL DUE TO THE DISCOMFORT OF THE SURGICAL SITE. THE FILM SHOWED THAT THE PLATE WAS BROKEN, AND HE WAS HOSPITALIZED IMMEDIATELY. ON (B)(6), INTERNAL FIXATION WAS REMOVED AND KIRSCHNER WIRE WAS USED FOR INTERNAL FIXATION. POSTOPERATIVE CONDITION IS STABLE. THE INCIDENT LED TO A SECOND OPERATION."
Patient problems: Failure of Implant; Implant Pain
MAUDE report 13018917 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page