NA 5820103017Recalls & reported problems
Stryker Corporation · 1.7mm Wire Pass Drill Bit · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 04546540362438), received between Jul 24, 2018 and Jul 29, 2025 — classified as 2 injuries, 6 malfunctions.
The most frequently reported specific device problem is “Fracture” (6 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture6
- Break2
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- No Known Impact Or Consequence To Patient2
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 29, 2025Fracture; Fracture
THIS REPORT SUMMARIZES 1 EVENT FOR THE FAILURE: FRACTURE. - 1 EVENT HAD NO HEALTH CONSEQUENCES OR IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22647295 ↗MalfunctionOct 22, 2024Fracture; Fracture
THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT IN WHICH THE DEVICE OR CUTTING ACCESSORY FRACTURED. - 1 EVENT HAD PATIENT INVOLVEMENT; NO PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20501546 ↗MalfunctionOct 23, 2023Fracture; Fracture
THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT IN WHICH THE DEVICE OR CUTTING ACCESSORY FRACTURED. - 1 EVENT HAD PATIENT INVOLVEMENT; NO PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17985894 ↗MalfunctionJun 29, 2021Fracture; Fracture
IT WAS REPORTED THAT DURING A SURGERY, THE DRILL BIT BROKE. IT WAS ALSO REPORTED THAT THERE WERE NO DELAYS AND NO ADVERSE CONSEQUENCES AS A RESULT OF THIS EVENT. IT WAS FURTHER REPORTED THAT THE PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12086194 ↗MalfunctionMar 1, 2021Break; Break
IT WAS REPORTED THAT THE DRILL BIT BROKE DURING A SURGICAL PROCEDURE. IT WAS ALSO REPORTED THAT THE BROKEN PIECE WAS RETRIEVED FROM THE PATIENT. IT WAS ALSO REPORTED THAT THERE WERE NO ADVERSE CONSEQUENCES AS A RESULT OF THIS EVENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11393583 ↗InjuryJun 22, 2020Fracture; Fracture
IT WAS REPORTED THAT AFTER A CRANIOTOMY PROCEDURE, A SURGEON NOTICED A METAL FRAGMENT IN THE SKULL BONE ON A CT IMAGE. IT WAS ALSO REPORTED THAT THE SURGEON PERFORMED A SURGERY TO REMOVE THE FRAGMENT THE NEXT DAY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10178414 ↗InjuryJun 15, 2020Fracture; Fracture
IT WAS REPORTED THAT DURING A CRANIOTOMY PROCEDURE, THE DRILL BIT BROKE AND REMAINED INSIDE THE PATIENT¿S SKULL BONE. IT WAS ALSO REPORTED THAT THE SURGEON DID NOT REALIZE THE BREAKAGE AT THE TIME. IT WAS FURTHER REPORTED THAT A WEEK LATER, A REVISION SURGERY WAS PERFORMED TO REMOVE THE BROKEN FRAGMENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10153394 ↗MalfunctionJul 24, 2018Break; Break
THIS REPORT SUMMARIZES 3 MALFUNCTION EVENTS IN WHICH THE DEVICE BROKE DURING USE. THERE WAS PATIENT INVOLVEMENT. TWO EVENTS OCCURRED DURING A CRANIAL PROCEDURE, 1 EVENT OCCURRED DURING A SURGICAL PROCEDURE. THERE WAS NO PATIENT IMPACT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7714599 ↗
FDA clearance and classification
The FDA regulates product code HBE (drills, burrs, trephines & accessories (simple, powered)) under 21 CFR 882.4310 as a Class II device. 21 CFR 882.4310 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the NA 5820103017
Has the NA 5820103017 been recalled?
No FDA recall record in our data names this exact device identifier (DI 04546540362438), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the NA 5820103017?
The FDA's MAUDE database lists 8 adverse event reports for this device, received between Jul 24, 2018 and Jul 29, 2025. In those reports, the most common specific device problems are “Fracture” (6) and “Break” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the NA 5820103017?
None of the reports are classified as deaths, 2 as injuries and 6 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the NA 5820103017, and is it still sold?
The FDA's device database lists Stryker Corporation as the company responsible for it (brand NA, model 5820103017). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) devices
- NA EMAX2PLUSSynthes GmbH · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)2,624 reports
- MIDAS REX MR8 MR8-AF02Medtronic Powered Surgical Solutions · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)930 reports
- Indigo™ 1845000Medtronic Xomed, Inc. · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)414 reports
- MIDAS REX MR8 MR8-AS07Medtronic Powered Surgical Solutions · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)221 reports
- Midas Rex MR8 MR8-AF02Medtronic Powered Surgical Solutions · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)186 reports
- MIDAS REX MR8 MR8-AA10Medtronic Powered Surgical Solutions · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)184 reports
- NA 5407-FA2-000Stryker Corporation · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)182 reports
- Indigo™ 1845000Medtronic Xomed, Inc. · DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)164 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page