GAMMA 1320-0066Recalls & reported problems
Stryker GmbH · Spreading Screwdriver, Ball Tip 8 mm · Class 1
All models of GAMMA (249)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04546540487667), received between Nov 5, 2018 and Apr 5, 2023 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Break” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break3
- Fracture2
Patient problems
- No Known Impact Or Consequence To Patient2
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 5, 2023Break; Fracture; Break; Fracture
AS REPORTED: "A SHORT GAMMA3 NAIL WAS REMOVED TO IMPLANT A HIP PROSTHESIS. WHEN REMOVING THE END CAP, THE DISTAL SCREWDRIVER HEAD OF THE INSTRUMENT BROKE OFF. OUR LOANER KIT WAS USED FOR THE EXTRACTION. ANOTHER SET OF INSTRUMENTS HAD TO BE ORDERED FROM ANOTHER HOSPITAL, WHICH RESULTED IN A SURGICAL DELAY OF ALMOST 60 MINUTES." AJ (B)(6) 2023, REP CONFIRMED THAT THE NAIL WAS INTACT AND IT WAS ONLY REMOVED AS PATIENT REQUIRED FULL PROSTHESIS. KT (B)(6) 2023: REP CONFIRMED THAT THE REASON FOR THE CONVERSION WAS A HIP JOINT ARTHROSIS AND THAT THE SURGEON WAS ABLE TO COMPLETE THE SURGERY SUCCESSFULLY AFTER GETTING AN ADDITIONAL INSTRUMENT KIT FROM ANOTHER HOSPITAL. REP FURTHER CONFIRMED THAT THE BROKEN TIP OF THE INSTRUMENT WAS REMOVED FROM THE PATIENT AND THAT ALL (THREE) PARTS WERE ALREADY RETURNED TO THE MANUFACTURER.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 16684056 ↗MalfunctionJul 30, 2019Fracture; Break; Fracture
THE DRIVER WAS BROKEN DURING THE GAMMA 3 IMPLANT PROCEDURE. A BACK-UP DEVICE WAS USED TO COMPLETE THE PROCEDURE. NO SURGICAL DELAY OR ADVERSE CONSEQUENCES WERE REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8843777 ↗MalfunctionNov 5, 2018Break
WHEN INSERTING THE END CAP, THE TIP OF THE SCREWDRIVER WAS DAMAGED AND REMAIN A BROKEN TIP BEHIND IN THE BODY. REMOVED THE DESTRUCTION AND COMPLETE THE PROCEDURE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8039724 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page