BIXCUT 0227-8510SRecalls & reported problems
Stryker GmbH · Reamer Shaft, Mod.Trinkle · Class 1
All models of BIXCUT (34)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04546540722317), received between Mar 5, 2020 and May 23, 2022 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Failure to Align” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Failure to Align2
- Residue After Decontamination2
- Detachment of Device or Device Component1
Patient problems
- Implant Pain2
- Loss of Range of Motion2
- Nerve Damage2
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMay 23, 2022Residue After Decontamination; Failure to Align; Residue After Decontamination; Failure to Align
IT WAS REPORTED THROUGH THE FILING OF A LAWSUIT THAT ALLEGEDLY THE PATIENT SUFFERED A RIGHT TIBIA AND FIBULA FRACTURE FROM A DIRT BIKE ACCIDENT AND ON (B)(6) 2020 THE PLAN WAS TO REMOVE A PILON PLATE THAT HAD BEEN PLACED IN THE PATIENT'S LEG TEN YEARS PRIOR AND REPAIR THE FRACTURE WITH INTRAMEDULLARY NAILING. A REAMER WAS SUPPOSED TO BE USED TO GO INTO THE TIBIA AND ALLEGEDLY "BOTH OF OUR REAMERS HAD FOREIGN MATERIAL FROM FORMER SURGERY" AND THEREFORE A "FLEXIBLE INTRA REAMER WAS THEN USED TO ENTER INTO THE CORRECT STARTING POSITION... THIS FLEXIBLE REAMER DID NOT FOLLOW THE GUIDE PIN AS HOPED AND MADE A SMALL 6-8 MM HOLE ON THE ANTERIOR CORTEX OF THE TIBIA." ALLEGEDLY HE CONTINUES TO SUFFER FROM KNEE PAIN, STIFFNESS AND TIGHTNESS, POSSIBILITY OF COMPARTMENT SYNDROME THAT MAY BE CAUSING HIS POSSIBLE NERVE INJURY.
Patient problems: Implant Pain; Loss of Range of Motion; Nerve Damage
MAUDE report 14469147 ↗MalfunctionMay 23, 2022Residue After Decontamination; Failure to Align; Residue After Decontamination; Failure to Align
IT WAS REPORTED THROUGH THE FILING OF A LAWSUIT THAT ALLEGEDLY THE PATIENT SUFFERED A RIGHT TIBIA AND FIBULA FRACTURE FROM A DIRT BIKE ACCIDENT AND ON 21-APR-2020 THE PLAN WAS TO REMOVE A PILON PLATE THAT HAD BEEN PLACED IN THE PATIENT'S LEG TEN YEARS PRIOR AND REPAIR THE FRACTURE WITH INTRAMEDULLARY NAILING. A REAMER WAS SUPPOSED TO BE USED TO GO INTO THE TIBIA AND ALLEGEDLY "BOTH OF OUR REAMERS HAD FOREIGN MATERIAL FROM FORMER SURGERY" AND THEREFORE A "FLEXIBLE INTRA REAMER WAS THEN USED TO ENTER INTO THE CORRECT STARTING POSITION... THIS FLEXIBLE REAMER DID NOT FOLLOW THE GUIDE PIN AS HOPED AND MADE A SMALL 6-8 MM HOLE ON THE ANTERIOR CORTEX OF THE TIBIA." ALLEGEDLY HE CONTINUES TO SUFFER FROM KNEE PAIN, STIFFNESS AND TIGHTNESS, POSSIBILITY OF COMPARTMENT SYNDROME THAT MAY BE CAUSING HIS POSSIBLE NERVE INJURY.
Patient problems: Implant Pain; Loss of Range of Motion; Nerve Damage
MAUDE report 14469127 ↗MalfunctionMar 5, 2020Detachment of Device or Device Component; Detachment of Device or Device Component
PRIMARY PROCEDURE, RIGHT TOTAL HIP ARTHROPLASTY. IT WAS REPORTED THAT THE SURGEON WANTED A FLEXIBLE REAMER. A TRINKLE BIXCUT SHAFT AND BIXCUT IM REAMER HEAD WERE USED. WHEN ASKED, THE SURGEON DECLINED THE USE OF THE GUIDE ROD WITH THE CONSTRUCT. AFTER REAMING, THE REAMER HEAD DISENGAGED FROM THE SHAFT IN THE PATIENT'S FEMUR. AFTER TRYING TO RETRIEVE THE DEVICE, THE SURGEON DECIDED TO LEAVE THE REAMER HEAD IN THE PATIENT. SURGERY WAS COMPLETED WITH A DELAY OF APPROXIMATELY 15 TO 20 MINUTES. REP REPORTED THAT NO FURTHER INFORMATION IS AVAILABLE.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 9795162 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page