BIXCUT 0227-8885SRecalls & reported problems
Stryker GmbH · Reamer Shaft, Mod.Trinkle · Class 1
All models of BIXCUT (34)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540722324), received between May 28, 2025 and May 28, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Fracture1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 28, 2025Break; Fracture; Break; Fracture
AS REPORTED: "DRILL FRACTURE WHEN DRILLING DISTAL AP LOCKING SCREW OF SUPRAPATELLAR NAIL. THE DRILL CAME OUT SHORT AND IT SHOWS DRILL BIT INTRAOSSEOUS POSTERIOR TO THE NAIL. PROCEDURE COMPLETED SUCCESSFULLY AS THERE WERE 2 ML LOCKING SCREWS USED. NO FURTHER DELAY. NO ADDITIONAL INTERVENTION REQUIRED. THE PLAN WAS TO USE 3 DISTAL LOCKING SCREWS TO OPTIMISE STABILITY IN THE POOR DISTAL TIBIA BONE QUALITY. RIGIDITY OF FIXATION RESULTED TO BE MARGINALLY INFERIOR. THE FRAGMENT IS INTRAOSSEOUS POSTERIOR TO THE NAIL, NOT FEASIBLE TO REMOVE. DISTAL END IS IN THE TIBIA."
Patient problems: Foreign Body In Patient
MAUDE report 22100886 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.