VariAx 54-25677SRecalls & reported problems
Stryker GmbH · VOLAR PLATE INTERMEDIATE LEFT, LONG · Class 2 · Implant
All models of VARIAX (345)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04546540729521), received between Apr 9, 2020 and Sep 20, 2023 — classified as 2 injuries.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Fracture1
- Material Twisted/Bent1
Patient problems
- Failure of Implant2
- Implant Pain1
- Injury1
- Wound Infection1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjurySep 20, 2023Break; Fracture; Break; Fracture
IT WAS REPORTED THAT A PATIENT REQUIRED REVISION SURGERY DUE TO BREAKAGE OF THE VARIAX PLATE AND INFECTION FROM THE RESULTING OPEN WOUND. BREAKAGE OF THE DEVICE WAS CONFIRMED ON X-RAY FOLLOWING PROGRESSIVE PAIN.
Patient problems: Failure of Implant; Implant Pain; Wound Infection
MAUDE report 17780326 ↗InjuryApr 9, 2020Material Twisted/Bent; Material Twisted/Bent
THE SURGEON REPORTED THAT THE PATIENT WAS REVIEWED IN FOLLOW UP CLINIC AND WITHE VARIAX DISTAL RADIUS PLATE HAD BENT. THE PATIENT WILL REQUIRE REVISION, BUT NO DATE HAS BEEN SET YET. ADDITIONALLY REPORTED: MOBILISATION INSTRUCTIONS: 2 WEEKS IN A BACK SLAP CAST, RETURN TO FRACTURE CLINIC AT 2 WEEKS FOR FUTURO SPLIT TO BE REMOVED FOR GENTLE MOBILISATION PATIENT COOPERATION: PATIENT SAYS FOLLOWED PLAN, ONLY USED HAND TO PLAY PLAYSTATION WITH SON.
Patient problems: Failure of Implant; Injury
MAUDE report 9946459 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page