NA 0206530000Recalls & reported problems
Stryker Corporation · Cartridge with Breakaway Femoral Nozzle · Class 1
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 2
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04546540857880), received between Jul 11, 2018 and Apr 6, 2023 — classified as 2 injuries.
The most frequently reported specific device problem is “Break” (1 report).
2 FDA recall records name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Recalls naming this device
- Aug 7, 2023Open, Classified
Potential for the Break-Away Femoral Nozzle the applicator tip connecting the cement cartridge, to disassemble or break off during use, can lead to the potential for loss of function of the ACM system and bio-incompatibility due to components falling into surgical site
Z-2597-2023 · Root cause: Under Investigation by firm · FDA record ↗
- Nov 9, 2017Terminated
Lack of sterility assurance as bioburden levels were found to be higher than internal acceptable rates.
Z-1244-2018 · Root cause: Environmental control · FDA record ↗
Most reported problems
Device problems
- Break1
- Fracture1
Patient problems
- Extravasation1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryApr 6, 2023Fracture; Fracture
IT WAS REPORTED THAT DURING A PROCEDURE AT THE USER FACILITY THE SURGEON PLACED THE LONG NOZZLE DOWN THE FEMORAL CANAL DURING CEMENTING AND IT INSTANTLY SNAPPED. THE BROKEN NOZZLE WAS RETRIEVED FROM THE PATIENT. BACK-UP EQUIPMENT WAS USED TO COMPLETE THE PROCEDURE. NO CLINICALLY SIGNIFICANT DELAY, NO ADVERSE CONSEQUENCES AND NO ADDITIONAL MEDICAL INTERVENTION WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16688227 ↗InjuryJul 11, 2018Break; Break
IT WAS REPORTED THAT DURING THE PROCEDURE, THE DEVICE SHATTERED. MEDICAL INTERVENTION TO REMOVE THE CEMENT THAT HAD ALREADY BEEN INJECTED WAS NECESSARY. THE PROCEDURE WAS SUCCESSFULLY COMPLETED AFTER OBTAINING A NEW DEVICE. NO FURTHER ADVERSE CONSEQUENCES WERE REPORTED.
Patient problems: Extravasation
MAUDE report 7678910 ↗
Other MIXER, CEMENT, FOR CLINICAL USE devices
- SMARTSET 5450-35-500Depuy (Ireland) · MIXER, CEMENT, FOR CLINICAL USE2 deaths965 reports
- NA 5049-11Zimmer, Inc. · MIXER, CEMENT, FOR CLINICAL USE1 recall389 reports
- ACM 0306573000Stryker Corporation · MIXER, CEMENT, FOR CLINICAL USE2 recalls9 reports
- NA 0206512000Stryker Corporation · MIXER, CEMENT, FOR CLINICAL USE2 recalls2 reports
- ACM 0306563000Stryker Corporation · MIXER, CEMENT, FOR CLINICAL USE1 recall44 reports
- AutoPlex, VertaPlex 0607687000Stryker Corporation · MIXER, CEMENT, FOR CLINICAL USE1 recall4 reports
- Revolution 0606573000Stryker Corporation · MIXER, CEMENT, FOR CLINICAL USE1 recall2 reports
- ACM 0306564000Stryker Corporation · MIXER, CEMENT, FOR CLINICAL USE1 recall0 reports