PROWATER AGH146300Recalls & reported problems
Asahi Intecc CO., Ltd. · Class 2
All models of PROWATER (3)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 04547327056144), received between Nov 8, 2020 and Dec 12, 2023 — classified as 4 injuries, 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component2
- Material Separation2
- Break1
- Material Deformation1
- Material Frayed1
Patient problems
- Device Embedded In Tissue or Plaque2
- No Clinical Signs, Symptoms or Conditions2
- Foreign Body In Patient1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 12, 2023Break; Break
PROWATER WIRE BECAME STUCK IN DISTAL LEFT MAIN/PROXIMAL LAD. PROWATER WIRE BECAME STUCK IN DISTAL LEFT MAIN/PROXIMAL LAD DURING CORONARY INTERVENTION. THE PHYSICIAN NOTICED THAT THE WIRE WAS BROKEN PRIOR TO ADVANCING ANY BALLOON OR STENT. THE PHYSICIAN WAS ABLE TO USE A BALLOON TO PIN THE WIRE TO THE GUIDE CATHETER AND REMOVE EVERYTHING.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18315432 ↗InjuryDec 11, 2023Material Separation; Material Separation
IT WAS REPORTED THAT AN ASAHI PROWATER GUIDE WIRE WAS USED DURING A PERCUTANEOUS CORONARY INTERVENTION (PCI) TO TREAT A MODERATELY CALCIFIED AND SEVERELY STENOSED LESION IN THE SEGMENT FROM THE LEFT MAIN TRUNK (LMT) TO THE LEFT ANTERIOR DESCENDING ARTERY (LAD). THE PROWATER GUIDE WIRE WAS FOUND STUCK BETWEEN THE DISTAL LMT AND THE PROXIMAL LAD AND DAMAGED. A BALLOON CATHETER WAS USED TO FIX THE PROWATER GUIDE WIRE IN AN UNSPECIFIED GUIDING CATHETER, AND THE DEVICES WERE REMOVED. THE PROCEDURE WAS COMPLETED WITH REESTABLISHED BLOOD FLOW BY STENTING. IT WAS INFORMED THAT THERE WERE NO ADVERSE PATIENT EFFECTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18299109 ↗InjuryMar 15, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT THE TIP OF AN ASAHI PROWATER GUIDE WIRE BECAME SEPARATED DURING A PERCUTANEOUS CORONARY INTERVENTION (PCI) TO TREAT A COMPLEX CALCIFIED AND HIGHLY TORTUOUS LESION IN THE RIGHT CORONARY ARTERY. THE LESION WAS BALLOONED, ROTABLADED, AND STENTED. THE PROWATER WAS USED DURING BALLOONING AND STENTING. DISSECTION PLANE DISTAL TO DISTAL STENT; THE DISSECTION WAS CREATED BY THE STENT AS IT SHOWED UP AFTER DEPLOYMENT. THE PHYSICIAN WENT BACK IN WITH THE PROWATER TO TRY TO ADDRESS THAT ISSUE. UPON THE THIRD INSERTION, THE WIRE WAS SHAPED WITH AN EXTRA "J" THE WIRE ENDED UP TRAPPED IN A RV MARGINAL. WHEN TRIED TO REMOVE THE CORSAIR, THE GUIDE WIRE FRAYED AND SEPARATED. THE PHYSICIAN ATTEMPTED TO USE A SNARE TO RETRIEVE THE REMAINING PART OF THE GUIDE WIRE, HOWEVER, COULD NOT RETRIEVE IT. BECAUSE BLOOD FLOW IN THE DISTAL RCA WAS BLOCKED, THE PATIENT WAS SENT TO BYPASS SURGERY. THE PATIENT WAS DOING WELL AFTER THE SURGERY.
Patient problems: Foreign Body In Patient
MAUDE report 11490119 ↗InjuryMar 12, 2021Material Frayed; Material Separation; Material Deformation
COMPLEX CALCIFIED LESION. BALLOONED, ROTABLADE, STENT. PROWATER USED DURING BALLOONING AND STENTING. DISECTION PLANE DISTAL TO DISTAL STENT. UPON THE THIRD INSERTION, THE WIRE WAS SHAPED WITH AN EXTRA 'J" THE WIRE ENDED UP TRAPPED IN AN RV MARGINAL. TRIED TO REMOVE WITH CORSAIR. WIRE FRAYED AND SEPERATED. TRIED SNARE. PATIENT SENT TO OR. PATIENT DOING WELL.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 11478059 ↗InjuryNov 8, 2020Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT THE TIP OF AN ASAHI PROWATER GUIDE WIRE BROKE OFF DURING A PCI TO TREAT A MODERATELY TORTUOUS LESION IN THE PROXIMAL RCA. THE GUIDE WIRE WAS ADVANCED TO THE LESION IN ATTEMPTS TO CROSS INTO THE PROXIMAL RCA STENT WITH ASSIST OF A NON-ASAHI GUIDELINER. WHEN THE PHYSICIAN ATTEMPTED TO PROLAPSE THE GUIDE WIRE, IT BECAME LODGED AND WHEN ATTEMPTING TO PULL BACK ITS TIP BECAME DISLODGED, AND FREE FROM ITS BODY. THE SEPARATED TIP OF THE GUIDE WIRE WAS UNSUCCESSFULLY RETRIEVED AND LEFT IN THE PATIENT. ANY ADVERSE EFFECTS ON THE PATIENT ASSOCIATED WITH THIS EVENT WERE NOT REPORTED.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 10806532 ↗
Other WIRE, GUIDE, CATHETER devices
- HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II 1009664Abbott Vascular Inc. · WIRE, GUIDE, CATHETER321 reports
- SYNCHRO 14 M00313010Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls220 reports
- PressureWire™ C12059Lightlab Imaging, Inc. · WIRE, GUIDE, CATHETER1 death296 reports
- SYNCHRO 2 M00326410Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls155 reports
- ENROUTE .014" Guidewire 11686-01Silk Road Medical, Inc. · Wire, Guide, Catheter2 deaths228 reports
- ARROW IPN035915Teleflex Incorporated · WIRE, GUIDE, CATHETER217 reports
- OmniWire Pressure guide wire 89185Philips Image Guided Therapy Corporation · Wire, Guide, Catheter1 recall1 death160 reports
- ARROW IPN055780Teleflex Incorporated · Wire, guide, catheter4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page