Radiolucent Head Frame 07-986-07Recalls & reported problems

Mizuho Corporation · Head Pin, (Radiolucent, Carbon 2) · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04946329237344), received between Mar 19, 2025 and Mar 19, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Loose or Intermittent Connection” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loose or Intermittent Connection1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 19, 2025Loose or Intermittent Connection; Loose or Intermittent Connection

    THIS DEVICE IS A SURGICAL INSTRUMENT USED TO HOLD THE CRANIUM IN PLACE DURING SURGERY. IT CONSISTS OF A TIP THAT IS INSERTED INTO THE PATIENT'S CRANIUM AND A BODY PART IN ONE PIECE. THREE OF THESE DEVICES WERE USED TO HOLD THE PATIENT'S CRANIUM IN PLACE DURING A NEUROSURGICAL PROCEDURE. AFTER THE SURGERY, WHEN THE HOSPITAL STAFF ATTEMPTED TO REMOVE THEM FROM THE PATIENT'S HEAD, THE CONNECTION BETWEEN THE TIP OF THE DEVICE AND THE MAIN BODY LOOSENED ON TWO OF THE THREE PIECES, CAUSING THE REMOVAL TO TAKE LONGER THAN USUAL. THE OCCURRENCE OF THIS EVENT PROLONGED THE ANESTHESIA TIME. THERE WERE NO RESIDUALS TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21645167 ↗

Other Holder, Head, Neurosurgical (Skull Clamp) devices

All Holder, Head, Neurosurgical (Skull Clamp) devices →