DISTAL HOOD DISTAL HOOD 12602 MAJ-1990Recalls & reported problems
Olympus Medical Systems Corp. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04953170314407), received between Jan 10, 2023 and Nov 25, 2024 — classified as 2 injuries.
The most frequently reported specific device problem is “Component Missing” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Component Missing1
Patient problems
- Hemorrhage/Blood Loss/Bleeding1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryNov 25, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
OLYMPUS REVIEWED THE FOLLOWING LITERATURE TITLED ¿LOW-POWER PURE-CUT HOT SNARE POLYPECTOMY FOR COLORECTAL POLYPS 10-14 MM IN SIZE: A MULTICENTER RETROSPECTIVE STUDY¿. BACKGROUND AND AIM: HOT SNARE EXCISION USING ELECTROCAUTERY IS WIDELY USED FOR LARGE COLORECTAL POLYPS (>10 MM); HOWEVER, ADVERSE EVENTS OCCUR DUE TO DEEP THERMAL INJURY. COLORECTAL POLYPS MEASURING 10¿14 MM RARELY INCLUDE INVASIVE CANCER. THEREFORE, LESS INVASIVE THERAPEUTIC OPTIONS FOR THIS SIZE CATEGORY ARE DEMANDING. WE HAVE DEVELOPED HOT SNARE POLYPECTOMY WITH LOW-POWER PURE-CUT CURRENT (LPPC HSP), WHICH IS EXPECTED TO CONTRIBUTE TO LESS DEEP THERMAL DAMAGE AND LOWER RISK OF ADVERSE EVENTS. THIS STUDY AIMED TO EVALUATE THE EFFICACY AND SAFETY OF LPPC HSP FOR 10¿14 MM COLORECTAL POLYPS, COMPARED WITH CONVENTIONAL ENDOSCOPIC MUCOSAL RESECTION (EMR). METHODS: IN THIS MULTICENTER, RETROSPECTIVE, OBSERVATIONAL STUDY, CLINICAL OUTCOMES OF EMR AND LPPC HSP FOR 10¿14 MM NONPEDUNCULATED COLORECTAL POLYPS BETWEEN (B)(6) 2021 AND (B)(6) 2022 WERE COMPARED USING PROPENSITY SCORE MATCHING. RESULTS: WE IDENTIFIED (B)(4). AFTER PROPENSITY SCORE MATCHING, THE BASELINE CHARACTERISTICS BETWEEN THE GROUPS WERE COMPARABLE, WITH (B)(
Patient problems: Hemorrhage/Blood Loss/Bleeding
MAUDE report 20775853 ↗InjuryJan 10, 2023Component Missing; Component Missing
AN OLYMPUS REPRESENTATIVE REPORTED TO OLYMPUS ON BEHALF OF THE CUSTOMER THAT AFTER AN ENDOSCOPIC EXAMINATION AND INSPECTION IS OVER, THIS DISTAL HOOD WAS MISSING. THE ENDOSCOPE WAS INSERTED AGAIN TO THE DESCENDING LEG OF THE DUODENUM, BUT THE HOOD COULD NOT BE FOUND. THE PATIENT REFUSED ADDITIONAL PROCEDURE AND WAS DISCHARGED HOME. A FOLLOW-UP WAS APPROVED. THERE WERE NO REPORTS OF PATIENT OR USER HARM ASSOCIATED WITH THIS EVENT. CASE WITH PATIENT IDENTIFIER (B)(6) REPORTS THE DISTAL HOOD USED IN THE PROCEDURE. CASE WITH PATIENT IDENTIFIER (B)(6) REPORTS THE EVIS LUCERA GASTROINTESTINAL VIDEOSCOPE USED IN THE PROCEDURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16134175 ↗
Other Gastroscope and accessories, flexible/rigid devices
- PENTAX Medical EG29-i10cHoya Corporation · Gastroscope And Accessories, Flexible/Rigid1,623 reports
- EVIS EXERA III GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF-1TH190Olympus Medical Systems Corp. · Gastroscope And Accessories, Flexible/Rigid4 recalls6 deaths1,025 reports
- EVIS EXERA lll GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF-XP190NOlympus Medical Systems Corp. · Gastroscope and accessories, flexible/rigid1 recall559 reports
- EVIS EXERA II GASTROINTESTINAL VIDEOSCOPE GIF-Q165Olympus Medical Systems Corp. · Gastroscope and accessories, flexible/rigid349 reports
- EVIS EXERA II GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF TYPE H180Olympus Medical Systems Corp. · Gastroscope and accessories, flexible/rigid1 death302 reports
- PENTAX EG27-i10Hoya Corporation · Gastroscope and accessories, flexible/rigid261 reports
- EVIS EXERA II COLONOVIDEOSCOPE OLYMPUS CF TYPE H180ALOlympus Medical Systems Corp. · Gastroscope and accessories, flexible/rigid2 deaths252 reports
- BALLOON MAJ-1351Olympus Medical Systems Corp. · Gastroscope and accessories, flexible/rigid174 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page