DISPOSABLE ELECTROSURGICAL SNARE SD-221L-25Recalls & reported problems
Olympus Medical Systems Corp. · Class 2
All models of DISPOSABLE ELECTROSURGICAL SNARE (13)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04953170326356), received between Nov 2, 2020 and Feb 9, 2022 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Perforation2
- Hemorrhage/Blood Loss/Bleeding1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryFeb 9, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT IS REPORTED IN THE LITERATURE TITLED "STUDY OF 109 CASES BY ENDOSCOPIC TREATMENT (ANTI-REFLUX MUCOSECTOMY: ARMS) FOR ACID SECRETION INHIBITOR (PPI) RESISTANT REFRACTORY GASTROESOPHAGEAL REFLUX DISEASE (GERD) (WITH VIDEO) ", THREE PATIENTS EXPERIENCED ADVERSE EFFECTS DURING OR AFTER AN ENDO-REFLUX MUCOSECTOMY (ARMS) USING A DISPOSABLE ELECTROSURGICAL SNARE. STUDY AIM: INVESTIGATE THE EFFICACY OF ARMS IN PATIENTS WITH PPI REFRACTORY GERD. METHOD: RETROSPECTIVE REVIEW OF 109 PATIENTS WITH PPI REFRACTORY GERD WHO UNDERWENT ARMS AND COMPARED THE QUESTIONNAIRE SCORES, ACID-EXPOSURE TIMES, NUMBER OF DEMEESTER SCORE, PROXIMAL REFLUX, AND PPI DISCONTINUATION RATES BEFORE AND AFTER ARMS. RESULTS: SUBJECTIVE SYMPTOMS WERE SIGNIFICANTLY IMPROVED (P<0.01) AND PPI COULD BE DISCONTINUED IN 40-50% OF THE PATIENTS AFTER ARMS. IN ADDITION, IMPROVEMENT IN SUBJECTIVE SYMPTOMS WAS MAINTAINED IN THE 3-YEAR FOLLOW-UP PATIENTS. ACID-EXPOSURE TIME OR DEMEESTER SCORE IMPROVED AFTER ARMS (P<0.01), BUT PROXIMAL REFLUX DID NOT IMPROVE SIGNIFICANTLY (P=0.0846). CONCLUSION: ARMS IS A VALUABLE MINIMALLY INVASIVE TREATMENT FOR PEOPLE WITH PPI REFRACTORY GERD. THE EFFECTIVENESS OF TREATMENT IS DUE TO INHIBITION
Patient problems: Hemorrhage/Blood Loss/Bleeding; Perforation
MAUDE report 13498125 ↗InjuryNov 2, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ON OCTOBER 7, 2020, OLYMPUS MEDICAL SYSTEMS CORP. (OMSC) RECEIVED LITERATURE TITLED "HOW TO MANAGE PERFORATION RELATED TO ENDOSCOPIC RESECTION OF SUPERFICIAL CANCER". THIS STUDY WAS REPORTED ENDOSCOPIC MUCOSAL RESECTION (EMR) OF A 5MM LARGE LESION OF THE ESOPHAGUS USED THE SUBJECT DEVICE. IN THE LITERATURE, IT WAS REPORTED THAT INTEROPERATIVE PERFORATION HAS OCCURRED. THE MUCOSAL RESECTION WAS IMPLEMENTED WITH THE SUBJECT DEVICE, AND THE DEFECT OF THE MUSCULAR SECTION WAS CONFIRMED. THE PERFORATION WAS MANAGED BY APPLYING ENDOSCOPIC CLIPPING. AFTER SURGERY, FASTING AND ANTIBACTERIAL TREATMENT WERE PERFORMED, AND THE PATIENT WAS DISCHARGED ON THE 8TH DAY. THERE ARE NO DESCRIPTIONS OF DEVICE RELEVANCE FOR ALL ADVERSE EVENTS IN THE LITERATURE. THERE IS NO DESCRIPTION OF THE DEVICE'S MALFUNCTION. BASED ON THE AVAILABLE INFORMATION, DETAILED INFORMATION OF THE SUBJECT DEVICE WAS NOT PROVIDED. WHEREAS, OMSC ASSUMES THAT THE PERFORATION WAS RELATED TO THE SUBJECT DEVICE DUE TO OCCURRED DURING THE PROCEDURE. THEREFORE, OMSC WILL SUBMIT A MEDICAL DEVICE REPORT (MDR) FOR THE PERFORATION.
Patient problems: Perforation
MAUDE report 10769893 ↗
Other Gastroscope And Accessories, Flexible/Rigid devices
- PENTAX Medical EG29-i10cHoya Corporation · Gastroscope And Accessories, Flexible/Rigid1,623 reports
- EVIS EXERA III GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF-1TH190Olympus Medical Systems Corp. · Gastroscope And Accessories, Flexible/Rigid4 recalls6 deaths1,025 reports
- EVIS EXERA lll GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF-XP190NOlympus Medical Systems Corp. · Gastroscope and accessories, flexible/rigid1 recall559 reports
- EVIS EXERA II GASTROINTESTINAL VIDEOSCOPE GIF-Q165Olympus Medical Systems Corp. · Gastroscope and accessories, flexible/rigid349 reports
- EVIS EXERA II GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF TYPE H180Olympus Medical Systems Corp. · Gastroscope and accessories, flexible/rigid1 death302 reports
- PENTAX EG27-i10Hoya Corporation · Gastroscope and accessories, flexible/rigid261 reports
- EVIS EXERA II COLONOVIDEOSCOPE OLYMPUS CF TYPE H180ALOlympus Medical Systems Corp. · Gastroscope and accessories, flexible/rigid2 deaths252 reports
- BALLOON MAJ-1351Olympus Medical Systems Corp. · Gastroscope and accessories, flexible/rigid174 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page