Skip to content

VISIGLIDE2 G-260-2527ARecalls & reported problems

Terumo Corporation · VISIGLIDE2 Single Use Guidewire · Class 2

All models of VISIGLIDE2 (6)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04953170358203), received between Jan 14, 2023 and Jan 14, 2023 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Material Separation” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Material Separation2

Patient problems

  • Insufficient Information2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 14, 2023Material Separation; Material Separation

    THE SALES REPRESENTATIVE REPORTED AN OUT OF BOX FAILURE FOR THE G-260-2527 A VIZIGLIDE WIRE INVOLVED. DURING THE PROCEDURE THE G-260-2527 A SNAGGED THE ELEVATOR OF THE T JF-Q 190V AND THE WIRE SNAPPED. THE PROCEDURE WAS ABLE TO BE COMPLETED USING A SECOND G-260-2527 A WIRE. THIS WAS AN OUT OF BOX FAILURE. ADDITIONAL INFORMATION WAS RECEIVED ON 11 JAN 2023: THE PROCEDURE PERFORMED WAS AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP). THE EVENT OCCURRED INTRA-OPERATIVE. THE PROCEDURE WAS COMPLETED WITH A SECOND DEVICE. THE PATIENT WAS IN STABLE CONDITION. THE PROCEDURE WAS SUCCESSFUL. THERE WAS NO BLOOD LOSS. THE DEVICE BROKE OUTSIDE THE BODY. THE USER OF THE DEVICE WAS ABLE TO PULL THE DEVICE BACK THRU THE SCOPE WHEN IT LOOKED DAMAGED AT APPROXIMATELY 6-7CM FROM THE DISTAL TIP.

    Patient problems: Insufficient Information

    MAUDE report 16169852 ↗
  • InjuryJan 14, 2023Material Separation; Material Separation

    THE SALES REPRESENTATIVE REPORTED AN OUT OF BOX FAILURE FOR THE G-260-2527 A VIZIGLIDE WIRE INVOLVED. DURING THE PROCEDURE THE G-260-2527 A SNAGGED THE ELEVATOR OF THE T JF-Q 190V AND THE WIRE SNAPPED. THE PROCEDURE WAS ABLE TO BE COMPLETED USING A SECOND G-260-2527 A WIRE. THIS WAS AN OUT OF BOX FAILURE. ADDITIONAL INFORMATION WAS RECEIVED ON 11 JAN 2023: THE PROCEDURE PERFORMED WAS AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP). THE EVENT OCCURRED INTRA-OPERATIVE. THE PROCEDURE WAS COMPLETED WITH A SECOND DEVICE. THE PATIENT WAS IN STABLE CONDITION. THE PROCEDURE WAS SUCCESSFUL. THERE WAS NO BLOOD LOSS. THE DEVICE BROKE OUTSIDE THE BODY. THE USER OF THE DEVICE WAS ABLE TO PULL THE DEVICE BACK THRU THE SCOPE WHEN IT LOOKED DAMAGED AT APPROXIMATELY 6-7CM FROM THE DISTAL TIP.

    Patient problems: Insufficient Information

    MAUDE report 16169849 ↗

FDA clearance and classification

The FDA regulates product code OCY (endoscopic guidewire, gastroenterology-urology) under 21 CFR 876.1500 as a Class II device. 21 CFR 876.1500 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the VISIGLIDE2 G-260-2527A

Has the VISIGLIDE2 G-260-2527A been recalled?

No FDA recall record in our data names this exact device identifier (DI 04953170358203), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the VISIGLIDE2 G-260-2527A?

The FDA's MAUDE database lists 2 adverse event reports for this device, received on Jan 14, 2023. In those reports, the most common specific device problem is “Material Separation” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the VISIGLIDE2 G-260-2527A?

None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the VISIGLIDE2 G-260-2527A FDA approved?

Devices of this type (product code OCY) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Terumo Corporation.

Who makes the VISIGLIDE2 G-260-2527A, and is it still sold?

The FDA's device database lists Terumo Corporation as the company responsible for it (brand VISIGLIDE2, model G-260-2527A). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.