Skip to content

PENTAX EC34-i10L (UDI 04961333225811)Recalls & reported problems

Hoya Corporation · PENTAX VIDEO COLONOSCOPE EC34-i10 SERIES · Class 2

All models of PENTAX (72)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Pentax video colonoscope is a flexible endoscope used to examine the colon. Many of the 844 reports describe parts breaking or detaching, display or image failures, optical blockages and fluid leaks. The reports include 4 injuries and no deaths. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
848
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 848 adverse event reports that list this exact device (DI 04961333225811), received between Aug 6, 2020 and Sep 30, 2026 — classified as 4 injuries, 844 malfunctions.

The most frequently reported specific device problem is “Break” (181 reports).

6 other recalls cover devices cleared under the same FDA submission (K131855); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 32 reportsDec 2023: 20 reportsJan 2024: 15 reportsFeb 2024: 16 reportsMar 2024: 20 reportsApr 2024: 13 reportsMay 2024: 16 reportsJun 2024: 14 reportsJul 2024: 17 reportsAug 2024: 6 reportsSep 2024: 15 reportsOct 2024: 6 reportsNov 2024: 8 reportsDec 2024: 1 reportsJan 2025: 12 reportsFeb 2025: 8 reportsMar 2025: 5 reportsApr 2025: 0 reportsMay 2025: 3 reportsJun 2025: 5 reportsJul 2025: 5 reportsAug 2025: 1 reportsSep 2025: 4 reportsOct 2025: 3 reportsNov 2025: 2 reportsDec 2025: 5 reportsJan 2026: 6 reportsFeb 2026: 2 reportsMar 2026: 2 reportsApr 2026: 2 reportsMay 2026: 7 reportsJun 2026: 0 reportsJul 2026: 3 reportsAug 2026: 7 reportsSep 2026: 4 reportsOct 2026: 0 reports20242025202632
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break181
  • Detachment of Device or Device Component117
  • Erratic or Intermittent Display115
  • No Display/Image107
  • Optical Obstruction95
  • Fluid/Blood Leak88
  • Obstruction of Flow74
  • Optical Distortion25

Patient problems

  • No Clinical Signs, Symptoms or Conditions837
  • Insufficient Information16
  • No Known Impact Or Consequence To Patient5
  • Device Embedded In Tissue or Plaque3
  • No Patient Involvement1

Recent adverse event reports

The 25 most recent of 848 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 30, 2026No Display/Image

    The time of event is unknown.There was no report of patient harm.Video image failure(Blackout ).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50942352 ↗
  • MalfunctionSep 2, 2026Detachment of Device or Device Component

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50558340 ↗
  • MalfunctionSep 2, 2026Optical Obstruction

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50558333 ↗
  • MalfunctionSep 1, 2026Detachment of Device or Device Component

    The time of event is unknown.There was no report of patient harm.Air/Water Nozzle peeled off (Black glue).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50536429 ↗
  • MalfunctionAug 18, 2026Optical Obstruction

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50292713 ↗
  • MalfunctionAug 13, 2026No Display/Image

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50232166 ↗
  • MalfunctionAug 13, 2026Optical Obstruction

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50232159 ↗
  • MalfunctionAug 10, 2026Erratic or Intermittent Display

    The time of event is unknown.There was no report of patient harm.Video image failure.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50189580 ↗
  • MalfunctionAug 10, 2026Detachment of Device or Device Component

    The time of event is unknown.There was no report of patient harm.Air/Water nozzle missing.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50189571 ↗
  • MalfunctionAug 7, 2026Detachment of Device or Device Component

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50170885 ↗
  • MalfunctionAug 3, 2026Fluid/Blood Leak

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50111526 ↗
  • MalfunctionJul 13, 2026Optical Obstruction

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25791977 ↗
  • MalfunctionJul 13, 2026No Display/Image

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(BLACKOUT ).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25791975 ↗
  • MalfunctionJul 2, 2026Detachment of Device or Device Component

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. AIR/WATER NOZZLE PEELED OFF (BLACK GLUE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25686785 ↗
  • MalfunctionMay 29, 2026Obstruction of Flow

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. OPERATION/SUCTION CHANNEL CLOGGED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25326956 ↗
  • MalfunctionMay 25, 2026Erratic or Intermittent Display

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25267461 ↗
  • MalfunctionMay 20, 2026Fluid/Blood Leak

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(FLUID DAMAGE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25225935 ↗
  • MalfunctionMay 19, 2026Optical Obstruction

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(SHADOW IN IMAGE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25212140 ↗
  • MalfunctionMay 18, 2026Detachment of Device or Device Component

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. AIR/WATER NOZZLE PEELED OFF (BLACK GLUE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25197196 ↗
  • MalfunctionMay 12, 2026Detachment of Device or Device Component

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. AIR/WATER NOZZLE PEELED OFF (BLACK GLUE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25146012 ↗
  • MalfunctionMay 1, 2026Detachment of Device or Device Component

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. AIR/WATER NOZZLE PEELED OFF (BLACK GLUE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25054097 ↗
  • MalfunctionApr 17, 2026Detachment of Device or Device Component

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. AIR/WATER NOZZLE PEELED OFF (BLACK GLUE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24906596 ↗
  • MalfunctionApr 3, 2026Optical Obstruction

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(SHADOW IN IMAGE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24780816 ↗
  • MalfunctionMar 13, 2026Erratic or Intermittent Display

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24587744 ↗
  • MalfunctionMar 9, 2026Fluid/Blood Leak

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(FLUID DAMAGE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24542420 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K131855. One submission often covers many models, so check the product and lot details in each record.

  • Z-2449-2021 · Jul 14, 2021 · Open, Classified
    Gastroscope Family # 1-Gastroscopes without a Water Jet Channel Models: EG-2790i, EG-1690K, EG-2490K, EG-2790K, EG27-i10; Gastroscope Family # 2- Gastroscopes with a Water Jet Chan
  • Z-2448-2021 · Jul 14, 2021 · Open, Classified
    Colonoscope Family # 1-Pentax Video Colonoscopes (EC Family) with One Instrument Channel and a Water Jet Channel Models: EC-2990Li, EC-3490Li, EC-3890Li, EC-3490TLi, EC-3490LK, EC
  • Z-1268-2020 · Jan 3, 2020 · Terminated
    Pentax Video Colonoscope Model: EC38-i10L
  • Z-1267-2020 · Jan 3, 2020 · Terminated
    Pentax Video Colonoscope Model: EC34-i10L
  • Z-0636-2017 · Aug 15, 2016 · Terminated
    Pentax Video Colonoscope is intended to be used with a PENTAX video processor (including light source), documentation equipment, Monitor, EndoTherapy Device such as a Biopsy Forcep
  • Z-2068-2016 · Apr 6, 2016 · Terminated
    Colonoscope Intended to provide optical visualization of and therapeutic access to the Lower Gastrointestinal Tract. This anatomy includes, but is not restricted to, the organs, ti

Other Colonoscope and accessories, flexible/rigid devices

All Colonoscope and accessories, flexible/rigid devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page