Quick summary

This Pentax Medical upper GI ultrasound video scope is an endoscope used to image the upper digestive tract. All 292 reports are malfunction reports, and many describe leaks, parts breaking, blocked flow, and the image going blank, flickering or showing shadows. The reports include no deaths and no injuries. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
295
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 295 adverse event reports that list this exact device (DI 04961333239498), received between Jul 2, 2021 and Sep 25, 2026 — classified as 295 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (64 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 4 reportsDec 2023: 2 reportsJan 2024: 2 reportsFeb 2024: 3 reportsMar 2024: 12 reportsApr 2024: 1 reportsMay 2024: 2 reportsJun 2024: 6 reportsJul 2024: 9 reportsAug 2024: 2 reportsSep 2024: 3 reportsOct 2024: 3 reportsNov 2024: 3 reportsDec 2024: 1 reportsJan 2025: 6 reportsFeb 2025: 3 reportsMar 2025: 1 reportsApr 2025: 3 reportsMay 2025: 2 reportsJun 2025: 1 reportsJul 2025: 3 reportsAug 2025: 3 reportsSep 2025: 1 reportsOct 2025: 4 reportsNov 2025: 4 reportsDec 2025: 6 reportsJan 2026: 1 reportsFeb 2026: 2 reportsMar 2026: 4 reportsApr 2026: 5 reportsMay 2026: 1 reportsJun 2026: 1 reportsJul 2026: 3 reportsAug 2026: 4 reportsSep 2026: 4 reportsOct 2026: 0 reports20242025202612
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak64
  • Break61
  • Obstruction of Flow42
  • No Display/Image35
  • Erratic or Intermittent Display31
  • Optical Obstruction24
  • Detachment of Device or Device Component12
  • Optical Distortion7

Patient problems

  • No Clinical Signs, Symptoms or Conditions293
  • Insufficient Information6

Recent adverse event reports

The 25 most recent of 295 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 25, 2026Erratic or Intermittent Display

    The time of event is unknown.There was no report of patient harm.Video image failure.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50893615 ↗
  • MalfunctionSep 24, 2026Fluid/Blood Leak

    The time of event is unknown.There was no report of patient harm.Video image failure(Fluid damage).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50877469 ↗
  • MalfunctionSep 18, 2026Erratic or Intermittent Display

    The time of event is unknown.There was no report of patient harm.Video image failure.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50813597 ↗
  • MalfunctionSep 8, 2026Fluid/Blood Leak

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50661474 ↗
  • MalfunctionAug 24, 2026Fluid/Blood Leak

    The time of event is unknown.There was no report of patient harm.Video image failure(Fluid damage).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50400858 ↗
  • MalfunctionAug 17, 2026Optical Obstruction

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50269329 ↗
  • MalfunctionAug 7, 2026Erratic or Intermittent Display

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50170873 ↗
  • MalfunctionAug 3, 2026No Display/Image

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50111535 ↗
  • MalfunctionJul 30, 2026Optical Obstruction

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50079003 ↗
  • MalfunctionJul 21, 2026Optical Obstruction

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25884948 ↗
  • MalfunctionJul 17, 2026Erratic or Intermittent Display

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25851043 ↗
  • MalfunctionJun 19, 2026Fluid/Blood Leak

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(FLUID DAMAGE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25557093 ↗
  • MalfunctionMay 18, 2026Optical Obstruction

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(SHADOW IN IMAGE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25197186 ↗
  • MalfunctionApr 15, 2026No Display/Image

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(BLACKOUT ).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24880670 ↗
  • MalfunctionApr 13, 2026No Display/Image

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(BLACKOUT ).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24854182 ↗
  • MalfunctionApr 8, 2026Fluid/Blood Leak

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE (FLUID DAMAGE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24812447 ↗
  • MalfunctionApr 3, 2026Break

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(OBJECTIVE LENS BROKEN).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24772970 ↗
  • MalfunctionApr 3, 2026No Display/Image

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(BLACKOUT ).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24772968 ↗
  • MalfunctionMar 30, 2026No Display/Image

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(BLACKOUT ).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24725175 ↗
  • MalfunctionMar 24, 2026Break

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24672143 ↗
  • MalfunctionMar 19, 2026Fluid/Blood Leak

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(FLUID DAMAGE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24636015 ↗
  • MalfunctionMar 4, 2026No Display/Image

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE (BLACKOUT).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24504096 ↗
  • MalfunctionFeb 24, 2026Fluid/Blood Leak

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(FLUID DAMAGE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24424840 ↗
  • MalfunctionFeb 17, 2026No Display/Image

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE (BLACKOUT).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24361014 ↗
  • MalfunctionJan 30, 2026Optical Obstruction

    THE TIME OF EVENT IS UNKNOWN. THERE WAS NO REPORT OF PATIENT HARM. VIDEO IMAGE FAILURE(SHADOW IN IMAGE).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24219020 ↗

Other Endoscopic Ultrasound System, Gastroenterology-Urology devices

All Endoscopic Ultrasound System, Gastroenterology-Urology devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page