VIDEO COLONOSCOPE EC34-I10TLRecalls & reported problems
Pentax Of America, Inc. · VIDEO COLONOSCOPE · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04961333242900), received between Nov 13, 2020 and Nov 13, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “Optical Distortion” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Optical Distortion1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 13, 2020Optical Distortion; Optical Distortion
PENTAX MEDICAL WAS MADE AWARE OF AN EVENT THAT OCCURRED AT A FACILITY IN (B)(6). AN MDPR WAS FILED WITH (B)(6). THE REPORTED INFORMATION IS AS FOLLOWS: THE HOSPITAL REPORTS, "THE FLEET OF PENTAX HIGH-DEFINITION COLONOSCOPES AND GASTROSCOPES AT JIM PATTISON OUTPATIENT CARE AND SURGERY CENTRE HAVE EXHIBITED ISSUES WHERE BLURRY ARTIFACTS ARE PRESENT IN ENDOSCOPY PROCEDURE IMAGES. THESE ARTIFACTS OBSCURE PARTS OF THE IMAGE AND LIMIT THE ABILITY OF STAFF TO CLEARLY IDENTIFY REGIONS OF INTEREST, SUCH AS POTENTIALLY CANCEROUS POLYPS. THE PREVALENCE OF THIS PROBLEM HAS BECOME A PATIENT SAFETY ISSUE, AS PATIENTS MAY RECEIVE FALSE NEGATIVE TEST RESULTS IN THE EVENT THAT A REGION OF INTEREST IS MISSED. TO UPDATE, 139 INCIDENT EVENTS HAVE BEEN REPORTED TO THE BC PATIENT SAFETY AND LEARNING SYSTEM REGARDING ISSUES WITH THIS FLEET OF SCOPES. IN AN EFFORT TO IDENTIFY THE ROOT CAUSE OF THIS PROBLEM, BIOMEDICAL ENGINEER HAS PARTNERED WITH ENDOSCOPY CLINICAL STAFF, MEDICAL DEVICE REPROCESSING DEPARTMENT LEADERSHIP, AND PENTAX TO CONDUCT A SYSTEMATIC VARIABLE-BY-VARIABLE INVESTIGATION. AT THE TIME OF THIS WRITING, THE INVESTIGATION GROUP HAS CONDUCTED LABORATORY ANALYSIS AND SITE WATER TESTING TO IDE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10837285 ↗
Other Colonoscope And Accessories, Flexible/Rigid devices
- EVIS EXERA lll COLONOVIDEOSCOPE OLYMPUS CF-HQ190LOlympus Medical Systems Corp. · Colonoscope and accessories, flexible/rigid3 recalls2 deaths6,804 reports
- EVIS EXERA III XENON LIGHT SOURCE OLYMPUS CLV-190Olympus Medical Systems Corp. · Colonoscope and accessories, flexible/rigid6,617 reports
- EVIS EXERA III GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF-HQ190Olympus Medical Systems Corp. · Colonoscope and accessories, flexible/rigid3 recalls5 deaths6,244 reports
- EVIS EXERA III GASTROINTESTINAL VIDEOSCOPE OLYMPUS GIF-H190Olympus Medical Systems Corp. · Colonoscope and accessories, flexible/rigid2 recalls7 deaths5,572 reports
- EVIS EXERA III COLONOVIDEOSCOPE OLYMPUS PCF-H190DLOlympus Medical Systems Corp. · Colonoscope and accessories, flexible/rigid3 recalls2,830 reports
- EVIS EXERA lll COLONOVIDEOSCOPE OLYMPUS PCF-H190LOlympus Medical Systems Corp. · Colonoscope and accessories, flexible/rigid3 recalls2 deaths2,513 reports
- EVIS EXERA lll COLONOVIDEOSCOPE OLYMPUS CF-H190IOlympus Medical Systems Corp. · Colonoscope and accessories, flexible/rigid1 recall1,967 reports
- PENTAX Medical EC38-i10cLHoya Corporation · Colonoscope and accessories, flexible/rigid1,618 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page