RUNTHROUGH 25-3011Recalls & reported problems

Terumo Corporation · RUNTHROUGH NS HYPERCOAT PTCA Guidewire · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
8
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 04987350720986), received between Mar 16, 2018 and Mar 6, 2025 — classified as 8 injuries.

The most frequently reported specific device problem is “Break” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 2 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break3
  • Material Separation3
  • Difficult to Advance2
  • Fracture1
  • Material Deformation1

Patient problems

  • Blood Loss4
  • Device Embedded In Tissue or Plaque3
  • Foreign Body In Patient2
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 6, 2025Material Deformation; Material Deformation

    THE USER FACILITY REPORTED THAT THE DISTAL WIRE TIP SEPARATED AWAY FROM THE MAIN BODY OF THE WIRE DURING A CORONARY INTERVENTION. AS A BAILOUT THE PHYSICIAN CHOSE TO STENT THE WIRE UP AGAINST THE VESSEL WALL. OUTCOME FOR THE PATIENT WAS SATISFACTORY. NO BLOOD LOSS WAS REPORTED. ADDITIONAL INFORMATION WAS RECEIVED ON 19FEB2025: THE PATIENT'S ANATOMY WAS PARTICULARLY TORTUOUS AT THE POINT OF SEPARATION. AN ACUTE ANGLE/TAKEOFF FROM THE PROXIMAL LAD INTO THE OSTIUM OF THE CIRCUMFLEX. STENTS WERE DEPLOYED IN THE CIRCUMFLEX, CIRCUMFLEX OSTIUM, AND PROXIMAL LAD. IT WAS NOTED THAT THE STENTS COVERED THE WIRE SEGMENT IN QUESTION PRIOR TO WIRE REMOVAL. APPROXIMATELY 3-4CM; ADDITIONALLY, THE WIRE SEGMENT THAT SEPARATED, WAS THE ESTIMATED LENGTH OF THE RADIOPAQUE MARKER. THE WIRE WAS STENTED PROXIMAL, AND OSTIUM OF CIRCUMFLEX AND PROXIMAL LAD. THE PATIENT WAS STABLE. THE INTENDED PROCEDURE WAS ABLE TO BE COMPLETED.

    Patient problems: Foreign Body In Patient

    MAUDE report 21536921 ↗
  • InjuryMar 6, 2025Material Separation; Material Separation

    THE USER FACILITY REPORTED THAT THE DISTAL WIRE TIP SEPARATED AWAY FROM THE MAIN BODY OF THE WIRE DURING A CORONARY INTERVENTION. AS A BAILOUT THE PHYSICIAN CHOSE TO STENT THE WIRE UP AGAINST THE VESSEL WALL. OUTCOME FOR THE PATIENT WAS SATISFACTORY. NO BLOOD LOSS WAS REPORTED. ADDITIONAL INFORMATION WAS RECEIVED ON 19FEB2025: THE PATIENT'S ANATOMY WAS PARTICULARLY TORTUOUS AT THE POINT OF SEPARATION. AN ACUTE ANGLE/TAKEOFF FROM THE PROXIMAL LAD INTO THE OSTIUM OF THE CIRCUMFLEX. STENTS WERE DEPLOYED IN THE CIRCUMFLEX, CIRCUMFLEX OSTIUM, AND PROXIMAL LAD. IT WAS NOTED THAT THE STENTS COVERED THE WIRE SEGMENT IN QUESTION PRIOR TO WIRE REMOVAL. APPROXIMATELY 3-4CM; ADDITIONALLY, THE WIRE SEGMENT THAT SEPARATED, WAS THE ESTIMATED LENGTH OF THE RADIOPAQUE MARKER. THE WIRE WAS STENTED PROXIMAL, AND OSTIUM OF CIRCUMFLEX AND PROXIMAL LAD. THE PATIENT WAS STABLE. THE INTENDED PROCEDURE WAS ABLE TO BE COMPLETED.

    Patient problems: Foreign Body In Patient

    MAUDE report 21536908 ↗
  • InjuryJun 24, 2020Material Separation; Material Separation

    THE USER FACILITY REPORTED THAT THE INVOLVED RUNTHROUGH DEVICE WAS USED DURING THE PROCEDURE AND SEPARATED ON WITHDRAWAL. THE PATIENT'S CONDITION WAS REPORTED GOOD AND WAS DOING FINE. THE PROCEDURE OUTCOME WAS GOOD. THE ESTIMATED BLOOD LOSS WAS LESS THAN 250CC. THERE WAS NO PATIENT INJURY, MEDICAL/SURGICAL INTERVENTION REQUIRED. ADDITIONAL INFORMATION WAS RECEIVED ON 10JUN2020. THERE WAS NO PART LEFT IN THE PATIENT. THE PROCEDURE BEING PERFORMED WAS A CORONARY ANGIOPLASTY.

    Patient problems: Blood Loss

    MAUDE report 10189414 ↗
  • InjuryJun 24, 2020Material Separation; Material Separation

    THE USER FACILITY REPORTED THAT THE INVOLVED RUNTHROUGH DEVICE WAS USED DURING THE PROCEDURE AND SEPARATED ON WITHDRAWAL. THE PATIENT'S CONDITION WAS REPORTED GOOD AND WAS DOING FINE. THE PROCEDURE OUTCOME WAS GOOD. THE ESTIMATED BLOOD LOSS WAS LESS THAN 250CC. THERE WAS NO PATIENT INJURY, MEDICAL/SURGICAL INTERVENTION REQUIRED. ADDITIONAL INFORMATION WAS RECEIVED ON 10JUN2020. THERE WAS NO PART LEFT IN THE PATIENT. THE PROCEDURE BEING PERFORMED WAS A CORONARY ANGIOPLASTY.

    Patient problems: Blood Loss

    MAUDE report 10189412 ↗
  • InjurySep 24, 2019Break; Difficult to Advance; Break; Difficult to Advance

    THE USER FACILITY REPORTED THAT WHILE APPROACHING A CORONARY, IN-STENT RESTENOSIS, IN THE LEFT MAIN, THE 180 CM LENGTH RUN THROUGH HYPER COAT BECAME CAUGHT/JAILED BEHIND THE STENT STRUT AS THE WIRE WAS ADVANCED; SUBSEQUENTLY THE WIRE SEPARATED APPROXIMATELY 10 CM FROM THE DISTAL TIP OF THE WIRE. THE REMAINDER OF THE PROXIMAL ASPECT OF THE WIRE WAS REMOVED; HOWEVER, THE DISTAL SEGMENT OF THE WIRE REMAINS LODGED BEHIND THE STENT STRUT AND LEFT MAIN VESSEL WALL. ADDITIONALLY, THE REMAINING PROXIMAL SEGMENT OF THE WIRE IS CIRCLING THE OPPOSING, CONTRALATERAL AORTIC ROOT. A SNARE WAS USED TO SNARE THE WIRE AND RETRIEVE WITHOUT SUCCESS. THE PATIENT WAS TURNED DOWN FOR SURGERY. ANOTHER ATTEMPT TO RETRIEVE THE WIRE MAY BE MADE ON A LATER DATE. BLOOD LOSS WAS LESS THAN 250 CC. THE PATIENT'S CONDITION WAS STABLE. CALCIFIED VASCULATURE, PREVIOUS BY-PASS PATIENT, LEFT MAIN IN-STENT RESTENOSIS. THE PROCEDURE OUTCOME WAS UNSATISFACTORY. ADDITIONAL INFORMATION WAS RECEIVED ON 09SEP2019. THE PROCEDURE TO REMOVE THE WIRE WAS PERFORMED ON (B)(6) 2019, WITH PARTIAL RETRIEVAL OF THE SPRING COIL SEGMENT OF THE WIRE. THE REMAINING DISTAL SEGMENT OF THE WIRE WOULD NOT RELEASE FROM THE STENT STRUT. THE AT

    Patient problems: Blood Loss; Device Embedded In Tissue or Plaque

    MAUDE report 9110972 ↗
  • InjurySep 24, 2019Break; Difficult to Advance; Break; Difficult to Advance

    THE USER FACILITY REPORTED THAT WHILE APPROACHING A CORONARY, IN-STENT RESTENOSIS, IN THE LEFT MAIN, THE 180 CM LENGTH RUNTHROUGH HYPERCOAT BECAME CAUGHT/JAILED BEHIND THE STENT STRUT AS THE WIRE WAS ADVANCED; SUBSEQUENTLY THE WIRE SEPARATED APPROXIMATELY 10CM FROM THE DISTAL TIP OF THE WIRE. THE REMAINDER OF THE PROXIMAL ASPECT OF THE WIRE WAS REMOVED; HOWEVER, THE DISTAL SEGMENT OF THE WIRE REMAINS LODGED BEHIND THE STENT STRUT AND LEFT MAIN VESSEL WALL. ADDITIONALLY, THE REMAINING PROXIMAL SEGMENT OF THE WIRE IS CIRCLING THE OPPOSING, CONTRALATERAL AORTIC ROOT. A SNARE WAS USED TO SNARE THE WIRE AND RETRIEVE WITHOUT SUCCESS. THE PATIENT WAS TURNED DOWN FOR SURGERY. ANOTHER ATTEMPT TO RETRIEVE THE WIRE MAY BE MADE ON A LATER DATE. BLOOD LOSS WAS LESS THAN 250 CC. THE PATIENT'S CONDITION WAS STABLE. CALCIFIED VASCULATURE, PREVIOUS BY-PASS PATIENT, LEFT MAIN IN-STENT RESTENOSIS. THE PROCEDURE OUTCOME WAS UNSATISFACTORY. ADDITIONAL INFORMATION WAS RECEIVED ON 09SEP2019. THE PROCEDURE TO REMOVE THE WIRE WAS PERFORMED ON (B)(6) 2019, WITH PARTIAL RETRIEVAL OF THE SPRING COIL SEGMENT OF THE WIRE. THE REMAINING DISTAL SEGMENT OF THE WIRE WOULD NOT RELEASE FROM THE STENT STRUT. THE ATTEN

    Patient problems: Blood Loss; Device Embedded In Tissue or Plaque

    MAUDE report 9110949 ↗
  • InjuryDec 28, 2018Break; Break

    TERUMO MEDICAL RECEIVED "AN" USER FACILITY MEDWATCH REPORT # (B)(4) ON DECEMBER 10, 2018. THE EVENT DESCRIPTION STATES THE FOLLOWING: THE USER FACILITY REPORTED THAT THE PATIENT UNDERWENT AN EMERGENT LEFT HEART CATHETERIZATION CORONARY ANGIOGRAPHY WITH A PERCUTANEOUS CORONARY INTERVENTION. DURING THE PLACEMENT OF THE STENT IN THE OM2 VESSEL THE TIP OF THE GUIDE WIRE BECAME STUCK UNDERNEATH THE STENT AND BROKE OFF. THE TIP OF THE GUIDEWIRE WAS REPORTED TO BE CAUGHT BETWEEN THE STENT AND THE CORONARY WALL. ADDITIONAL INFORMATION WAS RECEIVED ON 12/19/18: THE TIP OF THE GUIDEWIRE STILL REMAINS IN THE PATIENT. THE PATIENT IS IN STABLE CONDITION. A STENT PLACEMENT WAS USED WITH THE WIRE. BLOOD LOSS WAS LESS THAN 250CC.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 8202522 ↗
  • InjuryMar 16, 2018Fracture; Fracture

    THE USER FACILITY REPORTED THE DOCTOR WAS USING THE HYPERCOAT WIRE WHEN IT BECAME TANGLED IN A STENT, WHEN HE TRIED TO PULL THE WIRE BACK IT BECAME STUCK. ONCE HE WAS ABLE TO DISLODGE IT, THE TIP OF THE WIRE HAD COME APART. THE TIP WAS ASPIRATED OUT THROUGH A CATHETER AND NOTHING WAS LEFT IN THE PATIENT. PATIENT WAS NOT AFFECTED. ADDITIONAL INFORMATION WAS RECEIVED ON (B)(6) 2018. THE PATIENT WAS STABLE AND THE PROCEDURE OUTCOME WAS SUCCESSFUL. THE STENT THAT THE WIRE BECAME STUCK IN WAS AN ABBOTT STENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7346225 ↗

Other WIRE, GUIDE, CATHETER devices