CAPIOX CX*RX05REARecalls & reported problems
Terumo Corporation · CAPIOX RX Oxygenator · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04987350739025), received between Mar 6, 2025 and Mar 17, 2025 — classified as 1 death, 1 malfunction.
The most frequently reported specific device problem is “Failure to Deliver” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Deliver1
- Material Deformation1
Patient problems
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 17, 2025Material Deformation; Material Deformation
THE USER FACILITY REPORTED THAT THE OXYGENATOR INVOLVED WAS DEFECTIVE. THERE EVENT DID NOT RESULT IN DELAY IN THE BEGINNING OR CONTINUING THE SURGICAL PROCEDURE. THE OUT-FLOW CONNECTION UNDER RED CAPPED WAS BENT. THE PERFUSIONIST NOTED THE DEFECT DURING SETUP EXAMINATION, AND THE OXYGENATOR WAS NOT USED. THE PRODUCT WAS CHANGED OUT, AND THE SURGERY WAS COMPLETED SUCCESSFULLY. THERE WAS NO PATIENT INJURY, AND NO BLOOD LOSS WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21621533 ↗DeathMar 6, 2025Failure to Deliver; Failure to Deliver
THE USER FACILITY REPORTED THAT THE INVOLVED OXYGENATOR DID NOT FUNCTION PROPERLY. THE EVENT OCCURRED DURING CARDIOPULMONARY BYPASS. THE EVENT RESULTED IN DELAY IN BEGINNING OR CONTINUING THE SURGICAL PROCEDURE. AFTER 3 HOURS AND 40 MINUTES THE DEVICE'S ABILITY TO OXYGENATE WAS NOT FUNCTIONING. SWEEP WAS AT 1.2 LPM AND 60% FIO2, PO2 WAS 295 THEN NEXT ENTRY FELL TO 95 AND CONTINUED FALLING DESPITE INCREASES IN FIO2 AND SWEEP. A SECOND OXYGENATOR WAS ADDED TO THE RECIRCULATION LINE TO FACILITATE OXYGENATION. THEY DID NOT CHANGE OUT THE OXYGENATOR THEY ADDED ANOTHER OXYGENATOR TO THE CIRCUIT TO FINISH THE CASE. THE SURGERY WAS COMPLETED SUCCESSFULLY. NO BLOOD LOSS WAS REPORTED. A DEATH OCCURRED. THE PATIENT DID NOT DIE IN SURGERY, THEY DIED IN INTENSE CARE UNIT (ICU).
Patient problems: Insufficient Information
MAUDE report 21536636 ↗
FDA clearance and classification
The FDA regulates product code DTZ (oxygenator, cardiopulmonary bypass) under 21 CFR 870.4350 as a Class II device. 21 CFR 870.4350 ↗
Devices of this type normally need 510(k) clearance before sale.
The FDA lists this type of device as life-sustaining or life-supporting.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CAPIOX CX*RX05REA
Has the CAPIOX CX*RX05REA been recalled?
No FDA recall record in our data names this exact device identifier (DI 04987350739025), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CAPIOX CX*RX05REA?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between Mar 6, 2025 and Mar 17, 2025. In those reports, the most common specific device problems are “Failure to Deliver” (1) and “Material Deformation” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CAPIOX CX*RX05REA?
1 report is classified as a death, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the CAPIOX CX*RX05REA, and is it still sold?
The FDA's device database lists Terumo Corporation as the company responsible for it (brand CAPIOX, model CX*RX05REA). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other OXYGENATOR, CARDIOPULMONARY BYPASS devices
- HLS Set BEQ-HLS 7050 USAMaquet Cardiopulmonary AG · Oxygenator, Cardiopulmonary Bypass3 recalls13 deaths87 reports
- Affinity Fusion® BB811Medtronic, Inc. · OXYGENATOR, CARDIOPULMONARY BYPASS2 recalls90 reports
- HLS Set BEQ-HLS 5050 USAMaquet Cardiopulmonary AG · Oxygenator, Cardiopulmonary Bypass3 recalls4 reports
- NA HLS Set Advanced 5.0, Small Adult, BIOLINE CoatingMaquet Cardiopulmonary AG · OXYGENATOR, CARDIOPULMONARY BYPASS3 recalls0 reports
- A.M.G. PMP Sterile A.M.G. Module PMP NO T.P. SterileEurosets Srl · Oxygenator, Cardiopulmonary Bypass2 deaths106 reports
- CAPIOX®FX CX*FX25RWTerumo Corporation · Oxygenator, Cardiopulmonary Bypass2 deaths102 reports
- CAPIOX®RX CX*RX25RWTerumo Corporation · Oxygenator, Cardiopulmonary Bypass1 death102 reports
- QUADROX-i HMO 50000-USA #SQUADROX-i Small Adult, no FilterMaquet Cardiopulmonary AG · OXYGENATOR, CARDIOPULMONARY BYPASS2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page