The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05037881115504), received between Jul 20, 2026 and Jul 20, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Material Integrity Problem” (1 report).

1 other recall cover devices cleared under the same FDA submission (K162803, K955230); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Integrity Problem1

Patient problems

  • Hemorrhage/Blood Loss/Bleeding1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 20, 2026Material Integrity Problem

    Gelsoft Plus Bifurcate being implanted in a 44 year old male patient at (b)(6). A medial approach to the arm was made along the vascular pathway. Dissection was performed through layers until the brachial vein and superficial cutaneous brachial nerve were identified. Dissection of the deep layer was then performed, identifying the median nerve, brachial artery, and vein. The dissection extended into the axillary region, revealing no lesions at this level. Dissection continued distally, identifying the findings described 2 cm above the antecubital fossa. The proximal and distal edges of the brachial artery were reshaped. The brachial vein was ligated. A Fogarty suture No. 3-4-5 was passed proximally and distally, obtaining a single, fresh blood clot. The proximal and distal areas were irrigated with heparinized saline solution. A 6mm Dacron graft was placed with a proximal double-pillar anastomosis. Upon verifying the adequate seal of the anastomosis, it was confirmed that Hemorrhagic leakage was identified throughout the graft, so it was decided to remove it.No harm to the patient was noted , however it was considered a serious adverse event due to the increased surgery time.This r

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 25869386 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K162803, K955230. One submission often covers many models, so check the product and lot details in each record.

  • Z-2542-2021 · Jul 8, 2021 · Terminated
    The Instructions for Use (IFU) for: Gelsoft Plus Bifurcate, Gelsoft Plus Ax-Fem, GelsoftPlus ERS Ax-Fem, Gelweave Straight, Gelweave Trifurcate, Gelweave Ant-Flo, and Gelweave Val

Other PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER devices