Maxi Move KMCLXNRecalls & reported problems
Arjohuntleigh AB · Maxi Move, Low Height - Mobile Floor Lifter - Safe working load of 500 lb / 227 kg. · Class 1
All models of Maxi Move (5)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05055982764438), received between May 7, 2021 and May 7, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Detachment of Device or Device Component1
Patient problems
- Head Injury1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 7, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
ARJO WAS NOTIFIED ABOUT AN EVENT INVOLVING ARJO MAXI MOVE PASSIVE FLOOR LIFT AND PASSIVE CLIP SLING (MODEL NO MAA4000M-L, SERIAL NUMBER (B)(4)). IT WAS REPORTED THAT DURING PATIENT TRANSFER FROM A BEDSIDE TOILET TO A BED, THE CLIP DETACHED FROM A SPREADER BAR ATTACHMENT POINT (LUG). FOLLOWING INFORMATION PROVIDED BY THE CUSTOMER THE SLING CLIP DETACHED WHEN PATIENT, (WHO HAS CEREBRAL PALSY) WAS MOVING A LOT AND HER ARM HIT THE CLIP. AS A CONSEQUENCE OF THE EVENT PATIENT FELL OUT FROM THE SLING AND HIT HER HEAD ON THE CHASSIS LEG OF THE LIFT. THE PATIENT SUSTAINED A SMALL BUMP ON THE HEAD, INJURY WAS ASSESSED AS NOT SERIOUS.
Patient problems: Head Injury
MAUDE report 11789161 ↗
FDA clearance and classification
The FDA regulates product code FSA (lift, patient, non-ac-powered) under 21 CFR 880.5510 as a Class I device. 21 CFR 880.5510 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Maxi Move KMCLXN
Has the Maxi Move KMCLXN been recalled?
No FDA recall record in our data names this exact device identifier (DI 05055982764438), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Maxi Move KMCLXN?
The FDA's MAUDE database lists 1 adverse event report for this device, received on May 7, 2021. That report lists device problem “Detachment of Device or Device Component” (1); patient problem “Head Injury” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Maxi Move KMCLXN?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Maxi Move KMCLXN FDA approved?
Devices of this type (product code FSA) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Arjohuntleigh AB.
Who makes the Maxi Move KMCLXN, and is it still sold?
The FDA's device database lists Arjohuntleigh AB as the company responsible for it (brand Maxi Move, model KMCLXN). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Lift, Patient, Non-Ac-Powered devices
- Likorall™ overhead lift 3123001Liko AB · Lift, patient, non-ac-powered1 recall1 death32 reports
- Likorall™ overhead lift 3121001Liko AB · Lift, patient, non-ac-powered1 recall22 reports
- Likorall™ overhead lift 3124050Liko AB · Lift, patient, non-ac-powered1 recall17 reports
- Viking™ XL mobile lift 2040043Liko AB · Lift, patient, non-ac-powered1 recall14 reports
- Likorall™ overhead lift 3122010Liko AB · Lift, patient, non-ac-powered1 recall13 reports
- Medline MDS400ELBMedline Industries, Inc. · Lift, patient, non-ac-powered59 reports
- Uno™ mobile lift 2010004Liko AB · Lift, patient, non-ac-powered1 recall6 reports
- Likorall™ overhead lift 3122502Liko AB · Lift, patient, non-ac-powered1 recall5 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page