LifeStream LSMU0800737Recalls & reported problems
Clearstream Technologies Limited · LifeStream™ Balloon Expandable Vascular Covered Stent, 7 mm x 37 mm, 80 cm catheter length · Class 3 · Implant
All models of LifeStream (37)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 05391522081109), received between Jun 14, 2017 and Dec 13, 2024 — classified as 2 injuries, 3 malfunctions.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Dislodged or Dislocated3
- Appropriate Device Problem Term/Code Not Available1
- Failure to Advance1
- Material Split, Cut or Torn1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- No Known Impact Or Consequence To Patient1
- Rash1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 13, 2024Material Split, Cut or Torn; Material Split, Cut or Torn
IT WAS REPORTED THAT DURING A STENT GRAFT PLACEMENT PROCEDURE, THE STENT GRAFT ALLEGEDLY HAD A HOLE IN IT. THE PROCEDURE WAS COMPLETED BY RELINING THE ORIGINAL STENT WITH ANOTHER STENT. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20923017 ↗MalfunctionOct 21, 2023Failure to Advance; Device Dislodged or Dislocated; Failure to Advance; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A STENT GRAFT PLACEMENT PROCEDURE IN THE RIGHT COMMON ILIAC ARTERY VIA THE LEFT COMMON FEMORAL ARTERY APPROACH, THERE WAS TOO MUCH RESISTANCE FELT AND THE STENT GRAFT WAS ALLEGEDLY FAILED TO BE ADVANCED AFTER EXITING THE SHEATH. IT WAS FURTHER REPORTED THAT AFTER REMOVAL OF THE DELIVERY SYSTEM AND THE STENT TOGETHER WITH THE SHEATH, IT WAS FOUND THAT THE STENT GRAFT WAS ALLEGEDLY REMAINED ON THE GUIDEWIRE NOT ON THE BALLOON ITSELF. THE PROCEDURE WAS COMPLETED BY USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17982002 ↗MalfunctionAug 8, 2022Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A PROCEDURE, THE BALLOON ALLEGEDLY DISLODGED FROM THE STENT. IT WAS FURTHER REPORTED THAT THE PROCEDURE WAS COMPLETED BY USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15181754 ↗InjuryAug 2, 2019Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT AFTER STENT GRAFT IMPLANTATION, THE PATIENT ALLEGEDLY DEVELOPED A RASH ON THE RIGHT LEG WHERE THE DEVICE WAS PLACED.
Patient problems: Rash
MAUDE report 8855130 ↗InjuryJun 14, 2017Device Dislodged or Dislocated
IT WAS REPORTED THAT THE STENT DISLODGED FROM THE DELIVERY SYSTEM AND A SNARE WAS USED TO REPOSITION THE STENT. THERE WERE NO ANOMALIES NOTED DURING THE PREP OF THE DEVICE. THERE WAS NO DAMAGE NOTED TO THE BOX, TRAY OR STENT COVER AND THERE WAS NO DIFFICULTY REMOVING THE STENT COVER. THE TARGET LESION AS THE LEFT COMMON ILIAC ARTERY. THE VESSEL AND TRACKING PATH WERE NOT TORTUOUS OR CALCIFIED. THE PATIENT WAS BEING TREATED FOR AN ANEURYSM AT THE LEFT COMMON ILIAC ARTERY. A 0.035, 260CM AMPLATZ GUIDEWIRE AND A 7F, 10CM CORDIS SHEATH WAS USED. A CONTRALATERAL APPROACH WAS MADE. THE DEVICE WAS ADVANCED AND NO RESISTANCE WAS FELT DURING DEVICE TRACKING TO THE LESION. THE STENT DISLODGED OUTSIDE OF THE SHEATH WHILE THE HEALTH CARE PROVIDER ATTEMPTED TO REPOSITION THE DELIVERY SYSTEM IN AN 8MM VESSEL. A SNARE WAS USED TO REPOSITION THE STENT NEAR THE INTENDED PLACEMENT SITE IN THE ILIAC. THE SNARE CATHETER ENGAGED THE INNER PORTION OF THE STENT AND THIS ALLOWED A 0.018 GUIDEWIRE TO BE FED THROUGH THE STENT AND AN ULTRAVERSE DEVICE PASSED THROUGH. THE BALLOON WAS INFLATED SLIGHTLY AND THE STENT WAS CAPTURED. THE STENT WAS THEN IMPLANTED AT THE TARGET LESION. THERE WAS NO REPORTED ISSUES I
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6639954 ↗
Other Iliac covered stent, arterial devices
- GORE VIABAHN VBX Balloon Expandable Endo BXB073902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall2 deaths19 reports
- iCast Covered Stent System, 6mmX16mmX120cm 42616Atrium Medical Corporation · Iliac Covered Stent, Arterial1 recall15 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB057902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall2 deaths14 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB067902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall14 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB075902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall11 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB095902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall8 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB077902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall8 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB085902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall2 deaths8 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page