LifeStream LSMU0800758Recalls & reported problems
Clearstream Technologies Limited · LifeStream™ Balloon Expandable Vascular Covered Stent, 7 mm x 58 mm, 80 cm catheter length · Class 3 · Implant
All models of LifeStream (37)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 05391522081116), received between Sep 22, 2017 and May 7, 2025 — classified as 1 injury, 7 malfunctions.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (7 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Dislodged or Dislocated7
- Adverse Event Without Identified Device or Use Problem1
- Difficult to Open or Remove Packaging Material1
- Failure to Advance1
Patient problems
- No Clinical Signs, Symptoms or Conditions6
- Extravasation1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
InjuryMay 7, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ON (B)(6) 2025, A PATIENT UNDERWENT USING A STENT GRAFT PLACEMENT PROCEDURE USING LIFESTREAM STENT GRAFT TO TREAT LEFT BRACHIAL ACCESS AND LEFT COMMON FEMORAL ACCESS, ATTEMPTING REVASCULARIZATION OF A LEFT ILIAC ARTERY CHRONIC TOTAL OCCLUSION. A LIFESTREAM STENT WAS PREPPED AND DELIVERED TO THE SITE AND DEPLOYED WITHOUT COMPLICATION. ADDITIONAL ANGIOGRAPHY WAS PERFORMED AND SHOWED CONTINUED EXTRAVASATION AT THE MID STENT SITE. ANOTHER COVERED STENT WAS INSERTED AND DEPLOYED COVERING THE FULL LENGTH OF THE LIFESTREAM 7X58. FINAL ANGIOGRAPHY REVEALED CLOSURE OF THE PERFORATION. CURRENT STATUS OF THE PATIENT IS UNKNOWN.
Patient problems: Extravasation
MAUDE report 21974461 ↗MalfunctionNov 19, 2024Difficult to Open or Remove Packaging Material; Device Dislodged or Dislocated; Difficult to Open or Remove Packaging Material; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING THE PREPARATION OF A STENT GRAFT PLACEMENT PROCEDURE IN THE OCCLUDED COMMON ILIAC ARTERY VIA THE COMMON FEMORAL ARTERY APPROACH, THERE WAS ALLEGEDLY A DIFFICULTY IN REMOVING THE PROTECTOR FROM THE STENT. IT WAS FURTHER REPORTED THAT THE WHEN THE PROTECTOR WAS REMOVED WITH FORCE, THE PROXIMAL PART OF THE STENT HAD ALLEGEDLY BECAME LOOSENED. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO PATIENT CONTACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20730124 ↗MalfunctionOct 18, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A STENT GRAFT PLACEMENT PROCEDURE FOR CHRONIC TOTAL OCCLUSION LESION VIA IPSILATERAL APPROACH, THE LESION COULD NOT BE COVERED AND THE STENT GRAFT ALLEGEDLY DROPPED DURING LESION RETRACTION. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20479270 ↗MalfunctionFeb 20, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A STENT GRAFT PLACEMENT PROCEDURE IN THE RIGHT COMMON FEMORAL ARTERY VIA THE LEFT COMMON FEMORAL ARTERY, THE STENT ALLEGEDLY GOT DISLODGED FROM THE BALLOON. REPORTEDLY, A SNARE HAD TO BE UTILIZED TO RETRIEVE THE STENT GRAFT THAT HAD DETACHED FROM THE BALLOON MOUNT. THE PROCEDURE WAS COMPLETED BY USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18738830 ↗MalfunctionDec 13, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT PRIOR TO A STENT GRAFT PLACEMENT PROCEDURE, THE STENT ALLEGEDLY DISLODGED WITHIN THE SHEATH. THERE WAS NO PATIENT CONTACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18316668 ↗MalfunctionJan 31, 2022Failure to Advance; Device Dislodged or Dislocated; Failure to Advance; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE, THE PHYSICIAN ALLEGEDLY FELT RESISTANCE WHEN ADVANCING THE STENT TO THE LESION SITE. IT WAS FURTHER REPORTED THAT THE STENT WAS FOUND TO BE MISALIGNED FROM THE BALLOON AND WHEN THE PHYSICIAN TRIED TO PULL THE COVERED STENT BACK INSIDE THE SHEATH, THE DEVICE WAS UNABLE TO BE REMOVED AND GOT STUCK WITH THE SHEATH. THE DEVICE WAS FURTHER REPORTED TO HAVE MIGRATED OUTSIDE THE PATIENT. THE DEVICE WAS REMOVED OFF THE PATIENT AS ONE UNIT. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13391418 ↗MalfunctionNov 19, 2021Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE OF A CALCIFIED TARGET LESION IN THE EXTERNAL ILIAC ARTERY, THE COVERED STENT WAS MISALIGNED FROM THE BALLOON. THEREFORE, THE DEVICE WAS REMOVED FROM THE PATIENT. IT WAS FURTHER REPORTED THAT ANOTHER DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12841910 ↗MalfunctionSep 22, 2017Device Dislodged or Dislocated
IT WAS REPORTED THAT THE STENT DISLODGED. THE DEVICE WAS TO BE USED TO REPAIR AN ANEURYSM. THE DEVICE WAS BEING ADVANCED INTO A STEEP BEND IN THE ANATOMY AND THE STENT ALLEGEDLY CAME OFF OF THE BALLOON. THERE WAS ALSO ANOTHER LIFESTREAM DEVICE USED IN THIS PROCEDURE WHERE THE STENT ALSO DISLODGED. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6885732 ↗
Other Iliac covered stent, arterial devices
- GORE VIABAHN VBX Balloon Expandable Endo BXB073902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall2 deaths19 reports
- iCast Covered Stent System, 6mmX16mmX120cm 42616Atrium Medical Corporation · Iliac Covered Stent, Arterial1 recall15 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB057902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall2 deaths14 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB067902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall14 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB075902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall11 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB095902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall8 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB077902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall8 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB085902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall2 deaths8 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page