LifeStream LSMU1350758Recalls & reported problems

Clearstream Technologies Limited · LifeStream™ Balloon Expandable Vascular Covered Stent, 7 mm x 58 mm, 135 cm catheter length · Class 3 · Implant

All models of LifeStream (37)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 05391522081154), received between Aug 15, 2018 and May 20, 2026 — classified as 2 injuries, 4 malfunctions.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Dislodged or Dislocated6
  • Retraction Problem2
  • Device-Device Incompatibility1
  • Leak/Splash1
  • Migration or Expulsion of Device1

Patient problems

  • Blood Loss2
  • No Clinical Signs, Symptoms or Conditions2
  • No Consequences Or Impact To Patient1
  • No Patient Involvement1
  • Stenosis1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 20, 2026Migration or Expulsion of Device; Device Dislodged or Dislocated

    A PATIENT UNDERWENT A BALLOON EXPANDABLE STENT GRAFT PROCEDURE USING THE LIFESTREAM DEVICE. DURING THE PROCEDURE, THE SHEATH AND STENT BEGAN TO MIGRATE OFF THE BALLOON. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25225962 ↗
  • MalfunctionFeb 2, 2026Device Dislodged or Dislocated

    ON (B)(6) 2026, A PATIENT UNDERWENT FOR A STENT PLACEMENT PROCEDURE USING LIFESTREAM. PRIOR TO THE PROCEDURE, DURING INSTALLATION, THE LIFESTREAM COVERED STENT CAME OFF THE STENT BALLOON INSIDE THE SHEATH. THERE WAS NO PATIENT CONTACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24232135 ↗
  • InjuryJun 18, 2020Leak/Splash; Retraction Problem; Device Dislodged or Dislocated; Leak/Splash; Retraction Problem; Device Dislodged or Dislocated

    IT WAS REPORTED THAT THE STENT GRAFT ALLEGEDLY DISLODGED FROM THE DELIVERY SYSTEM DURING TREATMENT OF VERY CALCIFIED, BILATERAL ILIAC ARTERIES WITH 95% STENOSIS, AND WAS UNABLE TO BE RETRIEVED. IT WAS FURTHER REPORTED THAT ANOTHER STENT GRAFT WAS USED TO OPPOSE THE DISLODGED STENT AGAINST THE ARTERY VESSEL WALL. REPORTEDLY, THE PATIENT THEN HAD ALLEGED BLEEDING AND THE AREA WAS COVERED WITH AN ADDITIONAL COVERED STENT. PATIENT CURRENT STATUS WAS NOT PROVIDED.

    Patient problems: Blood Loss

    MAUDE report 10166391 ↗
  • InjuryJun 16, 2020Retraction Problem; Device Dislodged or Dislocated; Retraction Problem; Device Dislodged or Dislocated

    IT WAS REPORTED THAT THE STENT WAS PRESENT IN THE RIGHT EXTERNAL ILIAC ARTERY, THE DEVICE ALLEGEDLY DISLODGED FROM THE BALLOON. IT WAS FURTHER REPORTED THAT THE STENT COULD NOT BE RETRIEVED AND THE PATIENT FOUND TO BE BLEEDING. THE PATIENT STATUS IS UNKNOWN.

    Patient problems: Blood Loss; Stenosis

    MAUDE report 10157202 ↗
  • MalfunctionFeb 14, 2019Device-Device Incompatibility; Device Dislodged or Dislocated; Device-Device Incompatibility; Device Dislodged or Dislocated

    IT WAS REPORTED THAT THE BALLOON EXPANDABLE VASCULAR COVERED STENT WAS ALLEGEDLY DIFFICULT TO LOAD ONTO THE GUIDEWIRE. AFTER THE DELIVERY SYSTEM WAS PULLED OFF THE GUIDEWIRE, IT WAS IDENTIFIED THAT THE BALLOON EXPANDABLE VASCULAR COVERED STENT WAS ALLEGEDLY LOOSE ON THE DELIVERY SYSTEM. ANOTHER DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT CONTACT.

    Patient problems: No Patient Involvement

    MAUDE report 8339620 ↗
  • MalfunctionAug 15, 2018Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT DURING DEPLOYMENT OF THE BALLOON EXPANDABLE VASCULAR COVERED STENT IN THE ILIAC ARTERY, THE STENT WAS ALLEGEDLY DISLODGED AND NOT IMPLANTED IN DESIRED LOCATION. ANOTHER STENT WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7787301 ↗

Other Iliac covered stent, arterial devices

All Iliac covered stent, arterial devices →