LifeStream LSMU0800826Recalls & reported problems
Clearstream Technologies Limited · LifeStream™ Balloon Expandable Vascular Covered Stent, 8 mm x 26 mm, 80 cm catheter length · Class 3 · Implant
All models of LifeStream (37)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 05391522081178), received between Dec 19, 2018 and Feb 6, 2026 — classified as 10 malfunctions.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (9 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Dislodged or Dislocated9
- Device-Device Incompatibility2
- Failure to Advance1
Patient problems
- No Clinical Signs, Symptoms or Conditions8
- No Consequences Or Impact To Patient1
- No Patient Involvement1
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 6, 2026Device Dislodged or Dislocated
ON (B)(6) 2026, A PATIENT UNDERWENT A STENT PLACEMENT PROCEDURE UTILIZING A LIFESTREAM STENT. DURING THE PROCEDURE, IT WAS REPORTED THAT WHEN THE HEALTH CARE PROFESSIONAL ATTEMPTED TO ADVANCE THE STENT INTO THE SHEATH, THE STENT SLIPPED OFF THE BALLOON. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24275766 ↗MalfunctionSep 5, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
ON (B)(6) 2025, A PATIENT UNDERWENT A STENT GRAFT PLACEMENT PROCEDURE USING THE LIFESTREAM. UPON REPOSITIONING, IT WAS CONFIRMED THAT THE STENT HAD DISLODGED FROM THE SHEATH. THE GUIDING SHEATH WAS REMOVED AND REINSERTED, AFTER WHICH A STENT WAS SUCCESSFULLY DEPLOYED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22975122 ↗MalfunctionJun 2, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
ON (B)(6) 2025, A PATIENT WAS PREPPED FOR A STENT GRAFT PLACEMENT PROCEDURE USING THE LIFESTREAM. PRIOR TO THE PROCEDURE, THE STENT ALLEGEDLY BECAME LOOSE ON BALLOON AND SLID BACK ON THE CATHETER WHEN TRYING TO ADVANCE IT THROUGH A 7F SHEATH. ATTEMPTED TO RE-SECURE THE STENT ON THE BALLOON, IT WAS UNSUCCESSFUL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22125773 ↗MalfunctionOct 6, 2024Device-Device Incompatibility; Device Dislodged or Dislocated; Device-Device Incompatibility; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A STENT GRAFT PLACEMENT PROCEDURE IN THE RIGHT FEMORAL ARTERY LESION VIA THE CONTRALATERAL APPROACH, THE STENT ALLEGEDLY HAD STRONG RESISTANCE WHILE ENTERING AT THE HEMOSTATIC VALVE OF THE INTRODUCER SHEATH. IT WAS FURTHER REPORTED THAT THE STENT ALLEGEDLY HAD MISALIGNMENT WITH THE BALLOON. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20380318 ↗MalfunctionNov 15, 2023Failure to Advance; Device Dislodged or Dislocated; Failure to Advance; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE, THE STENT WAS ALLEGEDLY DIFFICULT TO BE DELIVERED WITH THE SHEATH PROTECTION. IT WAS FURTHER REPORTED THAT THE STENT WHICH HAD TO BE ADVANCED BARE WAS ALLEGEDLY MISALIGNED WITH THE MOUNTING BALLOON. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18138036 ↗MalfunctionOct 18, 2022Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE, THE STENT ALLEGEDLY DETACHED FROM THE BALLOON IN THE SHEATH. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15624394 ↗MalfunctionSep 20, 2022Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A STENT GRAFT PLACEMENT PROCEDURE, THE STENT ALLEGEDLY DISLODGED FROM THE DELIVERY SYSTEM. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15452998 ↗MalfunctionJul 27, 2022Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE, THE STENT WAS ALLEGEDLY DISLODGED UPON RETRACING BECAUSE THE PHYSICIAN FOUND MISTAKE SIZE CHOOSE. THE PROCEDURE WAS COMPLETED BY USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15109914 ↗MalfunctionJun 26, 2019Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT DURING TREATMENT OF THE MESENTERIC ARTERY VIA CALCIFIED AND TORTUOUS RIGHT COMMON FEMORAL ACCESS, THE STENT ALLEGEDLY DISLODGED FROM THE DELIVERY SYSTEM WHILE ADVANCING TO THE LESION; AS A RESULT, THE STENT GRAFT WAS SNARED AND REMOVED FROM THE BODY. IT WAS FURTHER REPORTED THAT NO ADDITIONAL STENTS WERE USED TO COMPLETE THE PROCEDURE DUE TO THE DEGREE OF CALCIFICATION IN THE LESION. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8737574 ↗MalfunctionDec 19, 2018Device-Device Incompatibility; Device-Device Incompatibility
IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE IN THE COMMON ILIAC ARTERY, THE BALLOON EXPANDABLE VASCULAR COVERED STENT DELIVERY SYSTEM FAILED TO INSERT THROUGH THE VALVE OF A 7X45 INTRODUCER SHEATH. ANOTHER DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT CONTACT.
Patient problems: No Patient Involvement
MAUDE report 8181190 ↗
Other Iliac covered stent, arterial devices
- GORE VIABAHN VBX Balloon Expandable Endo BXB073902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall2 deaths19 reports
- iCast Covered Stent System, 6mmX16mmX120cm 42616Atrium Medical Corporation · Iliac Covered Stent, Arterial1 recall15 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB057902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall2 deaths14 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB067902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall14 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB075902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall11 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB095902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall8 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB077902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall8 reports
- GORE VIABAHN VBX Balloon Expandable Endo BXB085902AW. L. Gore & Associates, Inc. · Iliac covered stent, arterial1 recall2 deaths8 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page